Model SL-4100
Features
• Light comes on when motion is detected.
• Automatically controls existing post light.
• D
ual
B
rite
®
Timer.
• Photocell keeps the light off during daylight
hours.
This package includes:
© 2007 HeathCo LLC
595-5657-04
TEST
Requirements
• The light control requires 120 volts AC.
• If you want to use Manual Override, the
control must be wired through a switch.
•
Some codes require installation by a
qualified electrician.
Motion Sensing Post
Light Adapter
3 Wire Connectors
3 Screws
Post Light
Adapter
ON-TIME
MINUTES
ACCENT
Put ON-TIME switch on the sensor bottom
to TEST and the D
ual
B
rite
®
(ACCENT)
switch OFF.
MANUAL MODE
... back on.
1 Second
OFF
then...
OPERATION
AUTO
Set ON-TIME switch to
1, 5, or 20 minutes.
Manual mode only works at
night because daylight re-
turns the sensor to AUTO.
Flip the light switch off for
one second then back on to
toggle between AUTO and
MANUAL MODE.
Manual mode works only
with the ON-TIME switch in
the 1, 5, or 20 position.
* resets to Auto Mode at dawn.
Note:
When first turned on wait about 1
1
/
2
minutes for the circuitry to calibrate.
Mode:
On-Time
Works: Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
DUSK TO DAWN
6 HOUR
3 HOUR
OFF
20
5
1
TEST
20
5
1
TEST
Before installation, record the model number
from back of fixture below. Attach receipt in
case of possible warranty issues.
Meets the ENERGY STAR
®
guidelines when D
ual
B
rite
®
function is off and ON-TIME
is 1 or 5 minutes.