-3-
598-1114-04
Bottom of Sensor
IMPORTANT
Avoid aiming the sensor at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where
pets or traffic may trigger the control.
•
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
... back on.
1 Second OFF
then
...
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
ON-TIME
TEST
1 5 20
AUTO
OPERATION
* resets to Auto Mode at dawn.
ON-TIME
D
ual
B
rite
®
TEST
TEST 1 5 20
Off 3 6 Dusk to
Dawn
Put ON-TIME switch
on the sensor bottom
to TEST and the D
ual
-
B
rite
®
switch OFF.
Put ON-TIME switch in the 1, 5,
or 20 minute position.
Mode:
On-Time
Works:
Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
MAX
MIN
RANGE
ON-TIME
DUAL BRITE™
TEST 1 5 20
MINUTES
OFF 3 6 DUSK TO
DAWN
HOUR
BO
O
S
T
Maximum
Maximum Range
Coverage Angle
15 ft.
(4.6 m)
70 ft. 100 ft.
(21 m) (30.5 m)
Boosted
240°
D
ual
Z
one
™
D
ual
Z
one
™
TEST AND ADJUSTMENT
1.
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
1
/
2
minute warm up period
before it will detect motion. When first turned
on, wait 1
1
/
2
minutes.
2. Turn the RANGE control to the medium position
(halfway between MIN and MAX), D
ual
B
rite
®
to OFF,
and the ON-TIME control to the TEST position.
Move ON-TIME Switch to
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST