background image

3

598-1327-01

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with 

surrounding temperature]

Sensing Angle . . . . . . . Up to 180°
Electrical Load . . . . . . . Up  to  500  Watt  Maximum 

Incandescent

Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST,  AUTO  and  MANUAL 

MODE

Time Delay  . . . . . . . . . 1, 5, 10 minutes
Replacement lamp . . . . T 500W (or less) halogen 120 

VAC

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features in 
products previously sold.

Motion

TEST AND ADJUSTMENT

 

Turn on the circuit breaker and light switch.

NOTE:  Sensor has a 1 

1

/

2

 minute warm up period be-

fore it will detect motion. When first turned on 
or when switching modes wait 1 

1

/

2

 minutes.

Bottom of Sensor

Avoid aiming the sensor at:

•  Objects  that  change  temperature  rapidly,  such  as 

heating  vents  and  air  conditioners.  These  heat 
sources could cause false triggering.

•  Areas where 

pets or traffic may trigger the control.

•  

Nearby large, light-colored objects reflecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.

 

Maximum Range 

Maximum

 

 

Coverage Angle

8 ft. 

(2.4 m)

70 ft.
(21 m)

  Least Sensitive 

Most Sensitive

Sensor

The detector is less sensitive to motion directly towards it.

180°

  Turn the RANGE control to the mid position and the 

ON-TIME control to the TEST position.

  Loosen the clamp screw in the 

sensor  ball  joint  and  gently 
rotate the sensor.

  Walk  through  the  coverage 

area  noting  where  you  are 
when the lights turn on. Move 
the  sensor  head  up,  down, 
or  sideways  to  change  the 
coverage area.

  Adjust the RANGE as needed. 

RANGE  set  too  high  may 
increase false triggering.

 

Secure  the  sensor  head’s 
aim by tightening the clamp 
screw.
 Do not overtighten the 
screw.

  Set the amount of TIME you 

want the lights to stay on after 
motion is detected (1, 5, or 10 minutes).

Clamp 
Screw

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

Motion

RANGE

10 5 1 TEST

ON-TIME

MIN 

MAX

Summary of Contents for SL-5310

Page 1: ...te may be needed Adaptors are available at Home Centers and Electrical Supply Stores S hook OPERATION resets to Auto Mode at dawn TEST TEST 1 5 10 ON TIME Put the ON TIME switch on the bottom of the sensor in the TEST position MANUAL MODE ON TIME TEST 1 5 10 back on AUTO 1 Second OFF then Move ON TIME Switch to 1 5 or 10 minutes Mode Switching Summary Flip light switch off for one second then back...

Page 2: ... an existing light with a wall switch for replacement Attach the lamp arm to the backplate arm and secure with the long bolt Note Whentighteningthearm screw pullonthewirestomake sure the wires are not pinched by the joint Remove the existing light fixture The S hook can be used to hold the fixture while wiring The small end of the hook can be inserted into a hole in the junction box The large end ...

Page 3: ...could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor Maximum Range Maximum Coverage Angle 8 ft 2 4 m 70 ft 21 m Least Sensitive Most Sensitive Sensor The detector is less sensitive to motion directly towards it 180 Turn the RANGE control to the mi...

Page 4: ...ively dark SYMPTOM Light stays on continuously Light flashes on and off Light flashes once then stays off in Manual Mode TROUBLESHOOTING GUIDE SYMPTOM Light will not come on Light comes on in day light Light comes on for no apparent rea son Light turns off too late in Dusk to Dawn setting POSSIBLE CAUSE 1 Light switch is turned off 2 Light is loose or burned out 3 Fuse is blown or circuit breaker ...

Page 5: ...ra MODO MANUAL préndalo 1 segundo APAGADO luego Mueva el interruptor de tiempo ON TIME a 1 5 ó 10 minutos Apague el interruptor por un segundo y préndalo de nuevo ON TIME TEST 1 5 10 Para AUTOMATICO Resumen de las modalidades del interruptor Para PRUEBA TEST 1 5 10 ON TIME Si se confunde mientras cambia de fases apague la electricidad por un minuto y préndala de nuevo Después del tiempo de calibra...

Page 6: ...es de la caja de empalmes con losalambresdelcontroldeluz Unalosyasegúrelos con un conector de alambre CUIDADO Para evitar los peligros de incendio o quemazón Deje que el elemento se enfríe antes de tocarlo La bombilla y el elemento funcionan a altas temperatu ras Mantenga al elemento por lo menos a 51 mm de los materiales combustibles No lo apunte hacia objetos que estén más cerca de 1 m Cambie só...

Page 7: ...1 m Evite apuntar del detector hacia Objetos que cambien rápidamente de temperatura tales como ductos de calefacción y acondiciona dores de aire Estas fuentes de calor pueden causar falsas alarmas Areas donde animales domésticos o el tráfico puedan activar el control Los objetos grandes cercanos y de colores res plandecientes que reflejan la luz del día pueden hacer que el detector se apague No ap...

Page 8: ...ida conti nuamente La luz se prende y se apaga La luz se prende una vez y luego permanece apa gada en la fase Manual SINTOMA La luz no se en ciende La luz se prende durante el día La luz se prende sin ninguna razón aparente La luz se apaga muy tarde en la calibración del Anochecer al Amanecer POSIBLE CAUSA 1 El interruptor de luz está apagado 2 El faro está flojo o fundido 3 El fusible está quemad...

Page 9: ...es 3 formats garniture de joint Crochet en S ESSAI Revient au mode automatique au lever du soleil FONCTIONNEMENT AUTOMATIQUE PRIORITÉ MANUELLE hors circuit pen dant 1 seconde puis à nouveau en circuit Placer l interrupteur ON TIME à 1 5 ou 10 minutes Mettre l interrupteur hors circuit pen dant une seconde puis le remettre en circuit Si vous ne savez plus dans quel mode se trouve l appareil couper ...

Page 10: ...e Pourfaciliterl installation choisirunappareild éclairage devant être remplacé et qui est déjà commandé par un interrupteur MONTER HORIZONTALEMENT Installation et remplacement de l ampoule Avant de remplacer l ampoule couper l alimenta tion et laisser refroidir le luminaire blanc blanc Raccorder le s fil s de terre du luminaire et la vis de terre de la plaque de garde au fil de terre de la boîte ...

Page 11: ...r modifier la zone de couverture Régler la sensibilité RANGE selon les be soins Une trop grande sensibilité pourrait cau ser des déclenchements intempestifs Pour une couvertureaccrue utiliser l amplification de portée Range Boost Fixer la tête du détecteur en position en serrant la vis de blocage Éviter de trop serrer la vis Placer l interrupteur ON TIME à 1 5 ou 10 minutes Vis de blocage Rotule P...

Page 12: ...liser un réglage de 3 h ou de 6 h SYMPTÔME Les lampes restent allumées continuellement Les lampes clignotent L éclairage clignote une fois puis reste éteint en mode manuel L éclairage s allume trop tard sous le réglage crépuscule aube SYMPTÔME Les lampes ne s allument pas Les lampes s allument le jour Les lampes s allument sans raison apparente CAUSE POSSIBLE 1 L interrupteurd éclairageestenpositi...

Reviews: