3
598-1131-01
Motion
Motion
TEST AND ADJUSTMENT
❒
Turn on the circuit breaker and light switch.
NOTE:
Sensor has a
1
1
/
2
minute calibration period
before it will detect motion.
When first turned on
wait
1
1
/
2
minutes.
Bottom of Sensor
Avoid aiming the sensor at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
Maximum Range
8 ft.
(2.4 m)
Maximum
Coverage Angle
70 ft.
100 ft.
(21 m) (30.5 m)
Boosted
Least Sensitive
Most Sensitive
Sensor
The detector is less sensitive to motion directly towards it.
❒
Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.
❒
Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cov-
erage area. Keep the sensor
at least 1" (2.5 cm) away
from the lamps.
❒
Adjust the RANGE as
needed.
RANGE set too high
may increase false
triggering.
❒
Secure the sensor head's
aim by tightening the
clamp screw. Do not over-
tighten the screw.
❒
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 20 minutes).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Sensing Angle . . . . . . Up to 240
°
Electrical Load . . . . . . Up to 300 W Max. Incandescent
[Up to 150 W Max. each lamp
holder].
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1 , 5, 20 minutes
DESA Specialty Products™ reserves the right to
discontinue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
240
°
B
O
O
S
T
MAX
MIN
RANGE
ON - TIME
TEST 1 5 2 0
MINUTES
❒
Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.