background image

3

598-1131-01

Motion

Motion

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE:

Sensor has a 

1

/

2

 

minute calibration period

before it will detect motion.

 

When first turned on

wait 

1

/

2

 

minutes.

Bottom of Sensor

Avoid aiming the sensor at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners.  These heat
sources could cause false triggering.

• Areas where pets or traffic may trigger the control.

• Nearby large, light-colored objects reflecting light

may trigger the shut-off feature. Do not point other
lights at the sensor.

Maximum Range

8 ft.

(2.4 m)

Maximum

Coverage Angle

70 ft.

100 ft.

(21 m) (30.5 m)

Boosted

Least Sensitive

Most Sensitive

Sensor

The detector is less sensitive to motion directly towards it.

Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.

Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cov-
erage area. Keep the sensor
at least 1" (2.5 cm) away
from the lamps.

Adjust the RANGE as
needed.

 

RANGE set too high

may increase false
triggering.

Secure the sensor head's
aim by tightening the
clamp screw.
 Do not over-
tighten the screw.

Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 20 minutes).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost.
[varies with surrounding
temperature]

Sensing Angle . . . . . .  Up to 240

°

Electrical Load . . . . . .  Up to 300 W Max. Incandescent

[Up to 150 W Max. each lamp
holder].

Power Requirements .  120 VAC, 60 Hz
Operating Modes . . . .  TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . .  1 , 5, 20 minutes

DESA Specialty Products™ reserves the right to
discontinue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.

240

°

B

O

O

S

T

MAX

MIN

RANGE

ON - TIME

TEST 1  5  2 0

MINUTES

Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.

Summary of Contents for SL-5330

Page 1: ...TIME switch on the sensor bottom to TEST MANUAL MODE ON TIME TEST 1 5 20 back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 20 minute position Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate Manual mode only works at night because daylight returns the sensor to AUTO Flipthelightswitchoffforonesecond thenbackontotogglebetweenAUTO and MANUAL MODE Ma...

Page 2: ...actory setting When screwing in the floodlamps do not overtighten For eave mount only Swing the sensor head towards the clamp screw joint Ifthesensorpopsoutoftheballjoint loosentheclamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Thenrotatethesensorheadclockwise180 sothe controls face down Wall Mount Eave Mount For under eave installation the sensor head mu...

Page 3: ...r head up down or sideways to change the cov eragearea Keepthesensor at least 1 2 5 cm away from the lamps Adjust the RANGE as needed RANGEsettoohigh may increase false triggering Secure the sensor head s aim by tightening the clamp screw Do not over tighten the screw Set the amount of TIME you want the lights to stay on after motion is detected 1 5 or 20 minutes Clamp Screw Ball Joint Aim Sensor ...

Page 4: ...UCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE AND SPECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDEN TAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR ...

Reviews: