background image

2

595-5730-05

INSTALLATION

For easy installation, select an existing light operated 
by a wall switch for replacement.

For best performance, mount the fixture about 8 ft. 
(2.4 m) above the ground.

W

ire

 

the

 L

ight

 C

ontroL

 

Turn power off at the fuse or circuit breaker.

 

  Remove the existing light fixture.

  Install mounting strap to junction box using screws 

appropriate for your junction box.

  The plastic hanger can be used to hold the fixture 

while wiring. The small end of the plastic hanger 
can be threaded through the hole in the center of 
the cover plate. The small end then goes into one 
of the slots on the mounting strap.

  Thread all fixture wires through the large holes in 

the gasket as shown.

  Connect the junction box wires to the light fixture 

wires as shown. Twist together and secure with wire 
connectors.

For eave mount only:

For under eave installation, the sensor head must 
be rotated

 as shown in the next two steps for proper 

operation and to avoid the risk of electrical shock.

M

ount

 

the

 L

ight

 C

ontroL

  Place  the  mounting  bolt  through  the  front  of  the 

junction box cover.

  Make sure the wire connectors and wires are inside 

the junction box. Align the mounting screw with the 
center hole in the mounting strap. Secure the fixture 
to the mounting strap.

  Push the rubber plug firmly into place.

  If not installed on a weatherproof box, 

caulk the 

wall plate and mounting surface

 with silicone.

Keep lamps at least 1" (2.5 cm) 
from the sensor. 

Black

 to 

Black

White

 to 

White

Gasket

Connect any fixture ground wire(s) and the cover plate 
ground screw to the junction box ground wire.

CAUTION: To Avoid Fire Or Burn Hazards:

•  Allow fixture to cool before touching. The bulb and 

the fixture operate at high temperatures.

•  Keep fixture at least 1" (2.5 cm) from combustible ma-

terials. Do not aim at objects closer than 3 ft. (1 m).

•  Use only T3, 150W (max.) tungsten halogen 120 

VAC lamps.

Rubber 

Plug

Mounting Bolt

B

uLB

 i

nstaLLation

NOTE:

 When re-lamping, 

turn power off

 and let the 

fixture cool.

  Open glass covers. To remove the old bulb push the 

bulb towards the right (with fixture as shown) until 
the left side of the bulb is clear of the left socket.

  To install a bulb, push the bulb into the right socket 

so the bulb fits completely into the left socket.

  Check that the bulb is seated properly.

  Close the glass covers.

Push the Rubber Plug over 
the mounting screw.

❒ 

Adjust the lamp holders by loosening the lock nuts 
but do not rotate the lamp holders more than 180° 
from the factory setting.

 Rotate the sensor head towards the clamp screw 

joint.

 

Then rotate the sensor head clockwise 180° so the 
controls face down.

Control Switch

Joint Clamp

If  the  sensor  pops  out  of  the  ball  joint,  loosen  the 
clamp screw and push the sensor back into the ball 
joint. Tighten the clamp screw when done.

Summary of Contents for SL-5514

Page 1: ... Auto Mode at dawn Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate MANUAL MODE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME TEST back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 10 minute position Put the ON TIME switch on the bottom of the sensor in the TEST position Manual mode only works at night because daylight returns the sensor to AUTO Flipthe...

Page 2: ... plug firmly into place If not installed on a weatherproof box caulk the wall plate and mounting surface with silicone Keeplampsatleast1 2 5cm from the sensor Black to Black White to White Gasket Connectanyfixturegroundwire s andthecoverplate ground screw to the junction box ground wire CAUTION To Avoid Fire Or Burn Hazards Allow fixture to cool before touching The bulb and the fixture operate at ...

Page 3: ... Time Delay 1 5 10 minutes Replacement lamp T3 150W halogen maximum 120 VAC HeathCo LLC reserves the right to discontinue prod ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold Loosen the clamp screw in the sensor ball joint and gently rotate the sensor Walk through the coverage area noting where you are when the ...

Page 4: ... KY 42102 9004 ATTN Technical Service If contacting Technical Service please have the following information available Model Number Date of Pur chase and Place of Purchase No Service Parts Available for this Product ONE YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province For a pe...

Page 5: ...ara PRUEBA préndalo Para AUTOMATICO 1 segundo APAGADO luego Ponga el interruptor de tiempo ON TIME en la posición de 1 5 ó 10 minutos Ponga el interruptor de tiempo ON TIME al fondo del detector en la posición de prueba TEST El modo manual funciona sólo por la noche porque la luz del día pone al detector en modo AUTOMATICO Apague el interruptor por un segundo y vuélvaloaprenderparaconmutarentre MO...

Page 6: ...a caja de empalme Mantenga las lámparas por lo menos a 2 5 cm del detector Instale El Control De Luz Pongaelpernodemontajeatravésdelfrentedelatapa de la caja de empalme Empuje el agujero pequeño de la empaquetadura sobre el tornillo de montaje Asegúresedequelosconectoresdecableyloscables estén dentro de la caja de empalme Alinee el tornillo de montaje con el agujero central de la lámina de montaje...

Page 7: ...stas fuentes de calor pueden causar falsas alarmas Areas donde animales domésticos o el tráfico puedan activar el control Los objetos grandes cercanos y de colores re splandecientes que reflejan la luz del día pueden hacer que el detector se apague No apunte otras luces hacia el detector Lo menos sensible Lo más sensible Detector Movimiento El detector es menos sensible del movimiento que se dirig...

Page 8: ...blar en inglés de 7 30 AM a 4 30 PM CST L V Usted puede también escribir a HeathCo LLC P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Servicio Técnico Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto GARANTÍA LIMITADA A 1 AÑO Esta es una Garant...

Page 9: ...ST 10 5 1 TEST ON TIME ESSAI AUTOMATIQUE Amener l interrupteur de temps en circuit ON TIME à la position cor respondant à 1 5 ou 10 minutes Amener en position d essai TEST l interrupteur de temps en circuit ON TIME du bas du détecteur Le mode manuel ne fonctionne que la nuit parce que la lumière du jour remet le capteur en mode AUTO Mettre l interrupteur hors circuit pendant une seconde plus en ci...

Page 10: ...jonction aux fils de l appareil d éclairage Les torsader ensemble et les fixer avec un serre fils AVERTISSEMENT Pour éviter les risques de brûlure ou d incendie Laisser l appareil refroidir avant de le toucher L ampoule et l appareil fonctionnent à haute température Garder l appareil à au moins 51 mm des matériaux combustibles Ne pas pointer vers des objets à moins de 1 m Utiliser seulement des am...

Page 11: ...age Éviter de trop serrer la vis Régler la durée d éclairage TIME après la détec tion d un mouvement Elle peut être réglée de 1 5 10 minutes Le moins sensible Le plus sensible Détecteur Mouvement Mouvement Le détecteur est moins sensible au mouvement dans sa direction Portée maximale 2 4 m Éviter de pointer l appareil en direction d objets dont la température change rap idement tels que des bouche...

Page 12: ...de main d oeuvre sera corrigée gratuitement Exclusions de la garantie Réparations réglage et calibrage dus à une mauvaise utilisation un mauvais traitement ou à la négli gence Les ampoules les piles et des autres articles non durables ne sont pas couverts par cette garantie Le service non autorisé ou la modification du produit ou d un ou l autre de ses composants fournis invalidera totalement la p...

Reviews: