IMPORTANT!
PLEASE READ THIS BEFORE INSTALLATION.

This thermostat is tested and certified by Pepper One Gmbh 
according to the requirements put forward by the Z-Wave 
Alliance. This is a Z-wave Plus product with the 500 series chip.
If the product does not work with your gateway, then the 
gateway manufacturer has not made an integration or 
implemented such a thermostat with their gateway.  
We do not give any guarantee towards integration.

PRINCIPLES FOR REGULATION

The Heatit Z-Wave thermostat is designed for controlling 
electrical heating cables and electrical radiators/convectors. 
The thermostat has 2 internal temperature sensors and has  
3 algorithms for temperature compensation. After you have  
set the temperature, the thermostat will use a hysteresis to 
regulate the temperature. The hysteresis is adjustable.

TEMPERATURE SHOWN IN DISPLAY

The temperature shown in the display is the actual temperature 
for floor sensor and the external room sensor. You are able to 
calibrate the sensor values.
When using the internal room sensor, the temperature shown 
is the set point. When using the internal sensor, the thermostat 
can seem somewhat inaccurate. This is due to heat generation 
inside the thermostat, draft and other external influences.

If the thermostat is to be used with waterbased heating systems, 
you have to use an external sensor.

SETUP

This manual describes the most essential functions and 
technical specifications of the thermostat. These instructions 
help the user to control the thermostat, and the electrician  
to install and setup the thermostat.

INSTALLATION

Installation must be done by a qualified electrical installer in 
accordance with the National Building codes. Before installation, 
disconnect any power to the thermostat’s mains. During 
installation of the thermostat, power to the thermostat must  
be disconnected AT ALL TIMES!

Use e.g. a small slotted screwdriver. Start by carefully removing 
the front cover by pushing the release springs. The front cover 
and the frame can now be removed. 

Now connect the wires to the thermostat’s terminals:

HEATING (N)  

Heating cable connection (Neutral)

N  

 

Power connection (Neutral) 230V

L  

 

Power connection (Live) 230V

HEATING (L)  

Heating cable connection (Live)

PILOT  

 

Pilot signal (ECO temp) 230V

FLOOR SENSOR   

NTC type (10, 12, 15, 22, 33 or 47kΩ). 

  Default 

10kΩ.

EXTERNAL SENSOR 

NTC type (10, 12, 15, 22, 33 or 47kΩ). 

  Default 

10kΩ.

Next, position the thermostat and fasten it onto the wall’s 
mounting box using 2-4 screws. Position the frame, then 
position and carefully press the front cover until it snaps in 
place. Check that the front cover has snapped in place properly 
on both left and right side. The front cover should now be firmly 
fixed on all sides.

STARTUP

AFTER CONNECTING THE POWER TO THE THERMOSTAT FOR THE 
FIRST TIME, ALL PARAMETERS WILL HAVE DEFAULT SETTINGS.

2 yr

HEATIT

 

Z-WAVE

      

Installers manual 

Firmware 1.8

  

01.06.2016 

Release spring

1: Left

3: Right

2: Center

87

 m

m

58

,8 m

m

HEA

TING L

 L

N

HEA

TING N

PIL

OT 

WIRE

FL

OOR

SENSOR

EX

TERNAL

SENSOR

Made in EU

TF 021

21,3 mm

51,1 mm

87

 m

m

58

,8 m

m

29,9 mm

Summary of Contents for HEATITZ-WAVE

Page 1: ...ecifications of the thermostat These instructions help the user to control the thermostat and the electrician to install and setup the thermostat INSTALLATION Installation must be done by a qualified electrical installer in accordance with the National Building codes Before installation disconnect any power to the thermostat s mains During installation of the thermostat power to the thermostat mus...

Page 2: ...f inclusion exclusion mode diF Hysteresis ALo Setting lowest allowed temperature limitation Airsensor AHI Setting highest allowed temperature limitation Airsensor FLO Setting lowest allowed temperature limitation Floor sensor FHI Setting highest allowed temperature limitation Floor sensor HEA Switch between heating and cooling function ESC Escape exit programming menu PRODUCT INFO Heatit Z Wave FE...

Page 3: ...n exclusion icon will appear in the display Confirmation will show Inc EcL in the display If inclusion fails Err error will appear HYSTERESIS DIF In this mode you are able to make changes to the hysteresis in the thermostat This means that you can changes the hysteresis from 0 2 C up to max 3 0 C Confirm with Center confirm button Default setting is 0 5 C When using a waterbased heating the recomm...

Page 4: ...Ignored 3 Floor sensor type 0 10k NTC 1 12k NTC 2 15k NTC 3 22k NTC 4 33k NTC 5 47k NTC 0 10k NTC Ignored 4 DIFF l Temperature control Hysteresis 3 30 0 3 C 3 0 C 5 0 5 C Ignored 5 FLo Floor min limit 50 400 5 0 C 40 0 C 50 5 0 C Ignored 6 FHi Floor max limit 50 400 5 0 C 40 0 C 400 40 0 C Ignored 7 ALo Air min limit 50 400 5 0 C 40 0 C 50 5 0 C Ignored 8 AHi Air max limit 50 400 5 0 C 40 0 C 400 ...

Reviews: