INTRODUCTION

Heatit Z-Smoke Multisensor is a wireless smoke sensor with built-in
PIR motion sensor, temperature sensor and emergency light.

INSTALLATION

Installation must be done by a qualified electrician in accordance
with the National Building Codes. Before installation, disconnect
any power to the smoke detector. During installation of the smoke
detector, power to the smoke detector must be disconnected AT
ALL TIMES!

•  Screw the mounting bracket onto the wall/ceiling. If used with
•  cable trunkings mount the adapter with the bracket mounted
•  on the bottom.
•  Unscrew the connection cover.
•  Connect the ”L” phase to one of the Wago connectors on the
•  back of the smoke detector and connect the ”N” phase to the
•  other Wago connector.
•  Switch on the switch. Illustrated below.
•  Align the four notches on the smoke detector with the hooks
•  on the mounting bracket. Rotate clockwise to lock the hook.

a. 

LED-indicator/function button/emergency light

b.  IR-lens
c. 

Buzzer

d.  Connection compartment fixing screw
e. 

Connection compartment

f. 

Hooks

g.  Mounting bracket
h.  Mounting holes (for the hooks on the mounting bracket)
i. 

Cable channel adapter

j. 

Mount by aligning notches and hooks

ADD/REMOVE

After power is appli ed, the smoke detector initiates a 1-minute
warm-up period. During this minute, the device will automatically
enter add/remove mode, and may now be added to the system
via the primary controller/gateway.
Please refer to your primary controller/gateway manual on how to
enter add/remove mode.

SERIAL CONNECTION

1. 

Add all smoke detectors to the same network.

2. 

Assign the smoke detectors to the correct zone/room in primary 
controller.

3. 

Access associations from the primary gateway (please refer to 
primary controller manual).

4. 

Assign associations from each device using association group 2 
(Sensor Basic Set) to all other smoke detectors.

 TECHNICAL DATA

Protocol  

 Z-Wave

Chip  

 

Z-Wave 500 chip

Battery 

 

230V AC 50Hz

 

 

200mAh, NiMh back-up battery

Temp. sensitivity  

 ±1°C

Alarm  

 

85dB at 3 meters distance

Smoke sensor  

 Photoelectric

Ambient temp.  

 

0°C to 50°C

Humidity  

 

Max. 85% RH

Range, PIR  

 

Up to 8m at 3m mounting height

IP Code  

 

IP 20

Size (LxWxH)  

 

105mm x 105mm x 41mm (ex. adapter)

Approvals  

 

Z-Wave Plus

 

 

CE, RoHS,

 

 

EN 14604:2005, 14604/AC:2008

Read the full manual at: 

manuals.heatit.com

HEATIT Z-SMOKE  

MULTISENSOR 

230V

Quick Guide

Ver 2022-A