background image

IMPORTANT
PLEASE READ THIS BEFORE INSTALLATION

This thermostat is tested and certified by Pepper One Gmbh 
according to the requirements put forward by the Z-Wave 
Alliance. This is a Z-wave Plus product with the 500 series chip.
If the product does not work with your gateway, then the 
gateway manufacturer has not made an integration or 
implemented such a thermostat with their gateway. 
We do not give any guarantee towards integration.

PRINCIPLES FOR REGULATION

The Heatit Z-TRM2 is designed for controlling electrical heating 
cables and electrical radiators/convectors. The thermostat 
has built in temperature sensors and has 3 algorithms for 
temperature compensation. After you have set the temperature, 
the thermostat will use a hysteresis to regulate the temperature. 
The hysteresis is adjustable.

TEMPERATURE SHOWN IN DISPLAY

The temperature shown in the display is the actual temperature 
for floor sensor and the external room sensor. You are able 
to calibrate the sensor values. When using the built in room 
sensor, the temperature shown is the set point. When using the 
built in sensor, the thermostat can seem somewhat inaccurate. 
This is due to heat generation inside the thermostat, draft and 
other external influences. If the thermostat is to be used with 
waterbased heating systems, you have to use an external sensor.
You may show the calculated temperature see parameter #17.

Z-WAVE THERMOSTAT – SETUP

This manual describes the most essential functions and 
technical specifications of the thermostat. These instructions 
help the user to control the thermostat, and the electrician to 
install and setup the thermostat.

FACTORY RESET

By pressing buttons Right and Center (down and confirm) for 20 
seconds, the thermostat will perform a complete factory reset.
NB! Please use this procedure only when the primary controller/
gateway is missing or otherwise inoperable.

BEHAVIOUR WITHIN THE Z-WAVE NETWORK

This product can be operated in any Z-Wave network with other 
Z-Wave certified devices from other manufacturers. All non-
battery operated nodes within the network will act as repeaters 
regardless of vendor to increase reliability of the network.

On delivery, the device does not belong to any Z-Wave network. 
The device needs to be added to an existing wireless network 
to communicate with the devices of this network. Devices can 
also be removed from a network. Both add and remove process 
are initiated by the primary controller of the Z-Wave network. 
This controller will be turned into a mode for adding or 
removing devices. Please refer to your primary controllers 
manual on how to turn your controller into add or remove 
mode. Only if the primary controller is in add or remove mode, 
this device can be added or removed from the network. When 
the device is removed from the network, it will set the device 
back to factory default.

If the device already belongs to a network, follow the remove 
process before adding it in your network. Otherwise, the adding 
of this device will fail.

INSTALLATION

Installation must be done by a qualified electrical installer in 
accordance with the National Building codes. Before installation, 
disconnect any power to the thermostat’s mains. During 
installation of the thermostat, power to the thermostat must be 
disconnected AT ALL TIMES!

Use e.g. a small slotted screwdriver. Start by carefully removing 
the front cover by pushing the release springs. The front cover 
and the frame can now be removed. 

Now connect the wires to the thermostat’s terminals:
Use 1,5mm² or 2,5mm² according to load.

HEATING (N)  

Heating cable connection (Neutral)

N  

 

Power connection (Neutral) 230V

L  

 

Power connection (Live) 230V

HEATING (L)  

Heating cable connection (Live)

PILOT  

 

230V pilot signal (ECO temp)

FLOOR SENSOR   

NTC type (10, 12, 15, 22, 33 or 47kΩ). 

  Default 

10kΩ.

EXTERNAL SENSOR 

NTC type (10, 12, 15, 22, 33 or 47kΩ). 

  Default 

10kΩ.

HEATIT 

Z-TRM2

  

Firmware 2.6

  

01.04.2018

Installers manual

Release spring

1: Left

3: Right

2: Center

Ver 2018-

A

Summary of Contents for Z-TRM2

Page 1: ...ble BEHAVIOUR WITHIN THE Z WAVE NETWORK This product can be operated in any Z Wave network with other Z Wave certified devices from other manufacturers All non battery operated nodes within the networ...

Page 2: ...u OFF Turns the thermostat off Sensors 1 A Choice of sensors Depending on your choice of sensors the menu will change 2 SEn Select the right Ohm value for your external floor sensor NTC type 10 12 15...

Page 3: ...re AHI Max Air room temperature PLo Min temperature in Power Reg Mode Confirm with Center confirm 8 HEA Choose whether the thermostat is to be used for heating or cooling ESC Leaving programming mode...

Page 4: ...e thermostat is able to operate in Setpoint for the heating mode setpoint for cooling mode and the setpoint for energy saving mode Thermostat Mode It is possible to change the operating mode of the th...

Page 5: ...ures commands Parameter 1 Parameter Size 1 Operation mode VALUE DESCRIPTION 0 Off Default 1 Heating mode 2 Cool mode not implemented 11 Energy saving heating mode Parameter 2 Parameter Size 1 Sensor m...

Page 6: ...rts can be also sent as a result of polling VALUE DESCRIPTION 0 Reporting of temperatures disabled 1 32767 1 second 32767 seconds Default is 60 seconds Parameter 23 Parameter Size 1 Temperature report...

Page 7: ...ties Generic Device Class Thermostat Specific Device Class Thermostat General V2 Approvals Z Wave Plus CE EN 60730 1 EN 60730 2 9 EMC 2014 30 EU RoHS 2011 65 EU LVD 2014 35 EU TERMINAL Use 1 5mm or 2...

Reviews: