background image

Note:  The Cozy Heat®  Heating Element 

is designed for in floor heating and space 

heating applications only. Product labeling 

may cross additional brands with same 

specifications as Cozy Heat® SR Cable 

Design and Installation 

  STEP 13         COMPLETE WARRANTY CERTIFICATE 

Mail in the warranty certificate for Cozy Heat®  and one for the ther-

mostat immediately after installing the Cozy Heat®  system.  Failure 

to do so could void the manufacturer’s warranty.  The warranty is 

subject to the guarantee conditions listed on the warranty certificate, 

and upon documentation that the required resistance readings were 

completed.  You may wish to keep a copy of the warranty card for 

your reference. 

The Cozy Heat®  system is now ready to use and enjoy!  Adjust the floor temperature sensing ther-

mostat until the floor reaches a comfortable level for floor warming applications.  For space heating 

applications adjust the thermostat to your comfort level, usually 65º to 70º F. 

 

Keep these instructions and all other owner/operating manuals for future reference. 

 

Note:  The Cozy Heat® SR Heating Element 

must be embedded in a cementitious material or 

installed in conduit. 

  STEP 12         COMPLETE AND ATTACH LABELS 

Place the included labels in the following locations: 

 

 Electrical Panel Label — Inside door at electrical service panel.   

 Stop Sign Warning Label — on or near the area to be floor warmed/in- floor  

heated by Cozy Heat®  

 

Note:  Make certain to record information from the Product Identification Label, if 

applicable.   

  STEP 11         TROUBLESHOOTING 

Problem:  Cozy Heat® Cable fails the Megohmmeter Test 

Potential Causes:    
  

 Inspect the Cozy Heat® Cable for damage to the insulator or braided ground and/or contact      

 

 

   between the braided ground and the core wires.  Repair the length of damaged Cozy Heat®  

    

 

   Cable with a splice kit or replace the entire length. 

 

 Call Heatizon Systems technical support 801-293-1232 

Note:  In the event the Cozy Heat

®

 Cable has not been damaged in any way call Heatizon Systems 

technical support @ 801-293-1232. For Warranty claims, please return the entire length of Cozy 

Heat®  to Heatizon Systems with requested forms (RMA, Warranty, Resistance Recording), with the 

end termination and power termination connections intact, for evaluation prior to replacement.   

Summary of Contents for Cozy Heat SR

Page 1: ...www heatizon com 2015 Heatizon Systems HEATIZON SYSTEMS RADIANT HEATING AND SNOW MELTING SYSTEMS Cozy Heat is a Registered Trademark of Heatizon Systems 01 15 Self Regulating Cable...

Page 2: ......

Page 3: ...Table Of Contents Product Overview 1 Cable Specifications 2 Cable Diagrams 3 Warnings and Reminders 4 Design and Installation 5 Resistance Recording Page 10 Warranty 11...

Page 4: ......

Page 5: ...e the NEC CEC and or local building codes for details Note The maximum insulation value of the floor ing material where Cozy Heat is installed should not exceed R 1 5 There is no limit for the insulat...

Page 6: ...If started at 40 F 0 F 20 F 505 475 420 650 560 765 765 9GM2 If started at 40 F 0 F 20 F 320 210 185 425 270 245 455 405 370 460 460 12GM2 If started at 40 F 0 F 20 F 240 155 135 315 210 180 375 310...

Page 7: ...SR Cable System Junction Box Power Distribution Panel Power Cable Ground Wire Heatizon Relay Panel Contactor Panel or Junction Box Cozy Heat SR Heating Element Cold Lead One Activation Device Cozy He...

Page 8: ...per square foot Cozy Heat SR braided grounding shield must be grounded to a suitable earth ground Always measure verify and record the actual re sistance at specific points throughout the installation...

Page 9: ...authorized Heatizon Systems distributor for more details Note that the minimum distance between the cables cannot be less than 1 inch Using a chalk line mark the desired location where each run of Co...

Page 10: ...o runs of Cozy Heat Heating Element and must extend out at least 10 inches away from the wall Warning Do not allow the sensor conduit to cross the Cozy Heat Heating Element Do not allow the sensor hea...

Page 11: ...Cozy Heat Heating Element is damaged contact Heatizon Systems at 801 293 1232 for repair options and do not cover Note Heatizon recommends that photographs of the installed Cozy Heat Heating Element b...

Page 12: ...turned on until cementitous material has fully dried a minimum of 7 days is recommended Once the cementitous material has dried measure and record resistance on Resistance Recording Table at the back...

Page 13: ...for future reference Note The Cozy Heat SR Heating Element must be embedded in a cementitious material or installed in conduit STEP 12 COMPLETE AND ATTACH LABELS 9 Place the included labels in the fol...

Page 14: ...low Customer Warranty Information 10 Name Address City State Phone Email Zip Purchased Product Details Watts Volts Watts Volts Ohms Sq Ft Model Size Serial Number Manufacture Date Tile Stone Vinyl Lam...

Page 15: ...e in writing no later than one 1 month following expiration of the warranty period and must be accompanied by the warranted part or compo nent Any claim not made in such manner shall not be honored by...

Page 16: ......

Page 17: ...Mail Heatizon Systems 4137 South 500 West Murray UT 84123 USA Phone 801 293 1232 Toll Free 888 239 1232 Fax 801 293 3077 Email info heatizon com Website www heatizon com...

Reviews: