HEATIZON.COM
10
• Make certain to plan for the movement of water created by melted snow.
• The transition joint between the heating element and the cold lead must be
embedded in asphalt, concrete, sand, stone dust, or cementitious material. Do not
bend the heating cable within 3” of cold connection.
• Activation Devices are the eyes and ears of the heating system. Location is important.
Please reference installation and operation information in the activation device product
literature. Some activation devices may or may not require a different voltage than the
heating cable.
Please consult Heatizon Systems for any other questions.
NOTE: