background image

INSTALLATION AND OPERATING INSTRUCTIONS

IMPORTANT:  

READ INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION OF LOG SET.

NOTE: DAMPER MUST BE OPEN ACCORDING TO CHART ON PAGE 3 OF THESE

INSTRUCTIONS OR FULLY OPEN WHEN LOG SET IS OPERATING.

This burner unit must be installed only in a fully-vented, solid-fuel burning fireplace with a working flue and constructed of
noncombustible material.  The damper and chimney must be free of any obstructions.  This log set is designed to burn with a
smoky, yellow flame and must be vented for this reason.  The fireplace chimney must have a permanent vent opening to the
atmosphere of not less than the minimum square inches stated in Table 1 and Table 2 on page 3 of these instructions.  If it is
smaller, do not use this log set.

IMPORTANT:

Ensure that the chimney draft is adequate by holding a lit match or candle at the top edge of the fireplace

opening.  This will indicate if air movement is toward the fireplace.  If draft is inadequate, do not operate logs until draft is
adequate.  
If you smell fumes from the burner in the room when the damper is fully open, it indicates that the fireplace draft
is insufficient.  If the draft is insufficient, have the chimney inspected by a qualified chimney sweep.  

DO NOT OPERATE

LOGS UNTIL THE FIREPLACE DRAFT IS CORRECTED.  

Do not burn solid fuels in a fireplace where a

decorative appliance is installed.

RHB SERIES GAS LOG BURNER

for

Champion and Radiance Log Sets

FOR YOUR SAFETY

Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS

+

Do not try to light any appliance.

+

Do not touch any electrical switch; do 
not use any phone in your building.

+

Immediately call your gas supplier from 
a neighbor’s phone.  Follow the gas 
supplier’s instructions.

+

If you cannot reach your gas supplier, 
call the fire department.

WARNING: 

Improper installation, adjustment, alteration, service or

maintenance can cause injury or property damage.  Refer to this manual.  For
assistance or additional information, consult a qualified installer, service agency or
the gas supplier.

14-2000

Summary of Contents for Gas Burner

Page 1: ...dequate do not operate logs until draft is adequate If you smell fumes from the burner in the room when the damper is fully open it indicates that the fireplace draft is insufficient If the draft is i...

Page 2: ...Fuel Gas Code ANSI Z223 1 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess o...

Page 3: ...0 18 Log Set 49 2 45 5 41 7 37 7 34 3 31 2 24 Log Set 56 6 52 4 48 2 43 2 39 8 35 9 Table 1 Minimum Opening Square Inches Minimum Permanent Free Opening Square Inches for Factory Built Fireplaces Chim...

Page 4: ...k of the fireplace as possible The fireplace will draft better with the burner unit toward the back of the fireplace Never place the burner assembly more toward the front in larger fireplaces 5 Remove...

Page 5: ...charred face of the log facing the room Line up the two holes in the bottom of this log with the two 3 8 pegs and gently slide the log over the pegs until it rests on the grate Do not force 2 Remove t...

Page 6: ...low Middle Log CHML 18 Glow Middle Log CHML 24 Back Log RAD 18 Back Log RAD 24 Back Log CHML 18 Back Log CHML 24 Left Middle Log RAD 18 Left Middle Log RAD 24 Left Middle Log CHML 18 Left Middle Log C...

Page 7: ...ty information previously listed above 2 Turn gas control handle clockwise to the OFF position 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas S...

Page 8: ...any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIG...

Page 9: ...position 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go...

Page 10: ...and logs 2 It is recommended that a qualified electrician do the installation 3 The wall switch kit has a wall switch and cover and is designed to be installed in a standard wall switch box NOTE The w...

Page 11: ...rol Valve Rotary 3 8 Black Street Elbow Screw 10 32 X 2 1 2 Square Nut 1 4 X 20 Valve Mounting Bracket Insulating Washer Burner Stainless Glow Burner Stainless Glow Valve Handle Bracket Insulating Mou...