Factory Reset
To reset the time clock to factory default settings, follow these steps:
• Use the Left / Right keys to scroll to SETUP .......................................................................
• Press and hold the Tick key for 10 seconds .......................................................................
• All of the icons on the display will appear for 2 seconds, then the display will
show two numbers.
• Use the Left / Right keys to select option number 2 (the selection will flash) ...
• Press the Tick key to confirm selection ................................................................................
The time clock will revert to the main display.
Note: Factory reset will cancel all parameters that were entered during the set-up and
pairing operations. These processes must be repeated after factory reset is completed.
Wiring Diagram -
neoStat-hw (S Plan)
This product must only be installed by a qualified electrician
and comply with local installation regulations.
N
COM
NO NC
L
N
L
TIMER
Stat-hw
N
L
N
L
BR
BL
GR
OR
Supply to
neoStat
Valve
Hot Water
Hot Water
Stat
End Switch
Boiler Enable
Fused Supply
to neoStat-hw
Series
Summary of Contents for NeoStat-hw