3
●
●
●
●
●
●
●
●
Testing the communications with the UH1-W
UH1-W:
Set the board address number on the UH1-W by selecting from
01-09 indicated on the dial.
Each UH1-W will need a different address.
PRT-UWTS:
Press Prog then Setup.
At the top of the screen press the Up button to select feature 05.
Use the up/down buttons in the centre of the screen to select
the UH1-W board number you are communicating with.(01-09)
Press the up button at the top of the screen to select feature 06.
Use the up/down buttons in the centre of the screen to select
which zone number on the UH1-W you are assigning the
thermostat to.(01-08)
Press the up button at the top of the screen to select feature 07.
Use the up/down buttons in the centre of the screen to select
if the thermostat will bring on the pump & boiler outputs.
00=UFH (Outputs enabled) 01=Radiator (Outputs not enabled)
Press the Done button.