14
Rev. 05/2020
MINIMUM CLEARANCE SEPARATION SPECIFICATIONS
The HEATMOR™ furnace, is certified to be installed outside, away from other
buildings. Please observe the following “Clearance to Combustibles” guidelines. If you
have any further questions, which are not addressed in this Operators Manual, please
contact your local dealer for further information.
♦
To HEATMOR™ Stainless Steel Outdoor Furnace
Back.
96 Inches
♦
To HEATMOR™ Stainless Steel Outdoor Furnace
Top.
18 Inches
♦
To HEATMOR™ Stainless Steel Outdoor Furnace
Front.
48 Inches
♦
To HEATMOR™ Stainless Steel Outdoor Furnace
Chimney.
96 Inches
♦
To HEATMOR™ Stainless Steel Outdoor Furnace
Sides.
6 Inches
♦
Do not
store combustible liquids or materials near the furnace.
♦
It is not recommended to install the furnace in any form of building.
Before installing your HEATMOR™ Stainless Steel Outdoor Furnace, if in the
United
States
, always check any and all applicable state and local regulations and inform
your insurance agent.
Before installing your HEATMOR™ Stainless Steel Outdoor Furnace, if in
Canada
,
always check any and all applicable Provincial and Municipal regulations and inform
your insurance agent.
HEATMOR™ strongly recommends not installing a HEATMOR™ Stainless Steel
Outdoor Furnace within 50 feet of any flammable structure.
A HEATMOR™ Stainless Steel Outdoor Furnace should be located with consideration
to your neighbor’s property and in accordance with local ordinances.
HEATMOR™ Outdoor Furnaces, Model 100 CSS, 200 CSS and 400 CSS are not
designed or certified to be located in densely populated areas.
CHAPTER 5