17
Rev. 05/2020
CHAPTER 7
4”
BASE: OUTDOOR FURNACE SITS ON THIS PAD
50”
58”
26”
12”
10”
PATIO STONES OR SEPARATE CEMENT SLAB
FOR CONVENIENT LOADING
48”
OUTDOOR FURNACE SITS HERE
ASH AUGER
LOADING AREA
GROUND
LEVEL
FOUR INCH GRAVEL BASE
CEMENT BASE
UNDERGROUND LINES
MODEL 100 PAD SPECIFICATIONS
The actual pad size is 50” x 58”. This gives
approximately 2” extra on all sides of furnace.
CAUTION: Do not exceed this length
measurement. Width can be wider if desired.
The bottom of the loading door is 24” above
ground or base of furnace. If you desire to
have the leading door higher, you can do so
by making the pad depth thicker.
Example: 12” instead of 4” or any figure in
between.
Patio stones or separate cement pad in front
of the loading door should
NOT
be attached
to main base of furnace.
It is recommended to use steel mesh or R-bar
in pad for strength.
Benefits to raising the pad:
1. Gives space below the ash auger to place
a pail for convenient ash removal.
2. Allows better visibility of the firebox.
3. Less bending when adding coal.
4. Keeps smoke above the operator.
5. Protects the base of the HEATMOR™.
PATIO STONES OR
SEPARATE CEMENT SLAB.
CEMENT BASE 4” - 12”
HIGHER THAN WHERE THE
OPERATOR STANDS.
LOADING
DOOR
SIDE VIEW
HOLES FOR HOOK-UPS
6”
AUGER