Front Light and Fan Power Switc
h
Principles
1) To provide light while fueling.
2) To provide a means of turning off the combustion air
blowers on demand.
3) To provide a visual warning that electrical power to the
combustion air blowers has been terminated.
Operation of the Front Light and Fan Power Switch
1) By adjusting the fan power switch to the down position,
the electrical power to the combustion air blower(s) is manually terminated, and the
front light turns on.
2) This light will then illuminate the area in front of the HEATMOR™.
3) The light must be turned off for electrical power to be running to the combustion air
blowers.
Removal and Replacement of the Front Light Bulb
1) Remove the glass globe by first loosening the setscrew
and then unscrew the globe.
2) Replace the light bulb.
3) Replace the globe and tighten the setscrew.
Removal and Replacement of the Fan Power/Light Switch
1) Turn off the main electrical power supply to the HEATMOR™.
2) Remove the switch cover plate.
3) Make a sketch of the location of the wires on the switch.
4) Remove the wires, and replace the switch. This is a special 3-way switch.
5) Replace the wires as in the diagram.
6) Secure the cover plate.
7) Turn the main electrical power supply back on to the HEATMOR™.
In the Event of a Power Failure
If a power failure occurs during the use of a HEATMOR™, do not open the firebox door
to provide draft for the fire to burn. Allow the fire to go out. In case of a prolonged power
failure, a generator should be used as a back-up power source.
It is recommended to contact a licensed
electrician to perform the above operation.
Front Light
Front Light &Fan Power Switch
IF THE HTF TEMPERATURE IS HIGH ENOUGH TO TRIGGER THE HIGH HTF
TEMPERATURE SAFETY SHUTOFF, THE FRONT LIGHT WILL NOT TURN ON
WHEN THE FAN POWER SWITCH IS IN THE DOWN POSITION.