61
chaPter 23
trOuBLeshOOtinG anD sOLutiOns
Main Principles to Remember
♦
Enough Wood.
♦
Enough Water.
♦
Fans On – Air Must Get In.
♦
Fans Off – Air Must Stay Out.
♦
Water Temperature between 165 and 185 degrees Fahrenheit.
PROCEDURES ARE REFERENCED TO EARLIER PARTS OF THIS HEATMOR™ “OPERATORS AND
MAINTENANCE MANUAL”.
PrOBLeM
cause
sOLutiOn
PrOceDure
Furnace Boils
Draft flipper stuck open.
Remove blower and
flipper assembly.
Clean, lube or replace.
Refer to
Steps to
“Maintain your Blower
and Flipper assembly.”
Draft Flipper not closing
100 percent.
Remove blower and
flipper assembly.
Clean, lube or replace.
Refer to
Steps to
“Maintain your Blower
and Flipper assembly.”
Blower, Flipper Assembly
plate not tight.
Tighten wing nuts.
Refer to
Steps to
“Maintain your Blower
and Flipper assembly.”
Ashes holding flipper
open in air box(s).
Clean out ashes.
Refer to
“air Box(s).”
Firebox door ajar, not
shut tight.
Close Fire Door Tight.
Refer to
“Firebox Door.”
Ash pan door not sealed
tight.
Close Cover Firmly.
Refer to
“ash Pan cover Plate.”
Flue cover plate(s) not
sealed.
Tighten ½ inch nuts.
Refer to
“Flue.”
Door gasket damaged.
Replace Gasket.
Refer to
“Firebox Door Gasket.”
Summary of Contents for 200 SSP