14
CHAPTER 7
6”
BASE: OUTDOOR FURNACE SITS ON THIS PAD
55”
86”
36”
9.5”
10”
PATIO STONES OR SEPARATE CEMENT SLAB
FOR CONVENIENT LOADING
48”
MODEL 400-4S CONCRETE PAD SPECIFICATIONS
The actual pad size is 55” x 86”. This gives
approximately 1” extra on all sides of furnace.
CAUTION: Do not exceed this length measurement.
Width can be wider if desired.
The bottom of the loading door is 25” above ground
or base of furnace. If you desire to have the leading
door higher, you can do so by making the pad depth
thicker.
Example: 12” instead of 4” or any figure in between.
Patio stones or separate cement pad in front of the
loading door should
NOT
be attached to main base
of furnace.
It is recommended to use steel mesh or R-bar
in pad for strength.
Benefits to raising the pad:
1. Gives space below the ash cleanout to place a pail
for convenient ash removal.
2. Allows better visibility of the firebox.
3. Less bending when adding wood.
4. Keeps smoke above the operator.
5. Protects the bottom of the HEATMOR™
.
HOLES FOR HOOK-UPS
OUTDOOR FURNACE SITS HERE
GROUND
LEVEL
UNDERGROUND LINES
FIREBOX
DOOR
SIDE VIEW
OUTDOOR FURNACE SITS HERE
FOUR INCH GRAVEL BASE
CEMENT BASE
LOADING AREA
CEMENT BASE 4” - 12”
HIGHER THAN WHERE
THE OPERATOR STANDS.
PATIO STONES OR
SEPARATE CEMENT SLAB.
Summary of Contents for 400-4S
Page 1: ...Outdoor Furnaces TM SAVE THESE INSTRUCTIONS...
Page 10: ...5 HEATMOR Stainless Steel Outdoor Furnace Model 400 4S Chapter 1...
Page 73: ...68...
Page 88: ...83 PROBLEM CAUSE SOLUTION PROCEDURE...
Page 92: ...87 Outdoor Furnaces...
Page 93: ...88 NOTES...
Page 94: ...89 wiring diagram...
Page 95: ...90 Revised Manual on 07 11 12...