70
7.
Q. Why am I experiencing an excess build up of creosote in the furnace?
A.
You more than likely are introducing unwanted draft into the firebox. This may be caused by several
things, including a door ajar, ash auger tube cover loose, flipper assembly stuck. If your furnace
is in a location where wind may effect the pressure differential across the furnace, it could
cause draft to leak past the flipper.
Refer to:
• Creosote Build-up (Located in Trouble Shooting and Solutions).
8.
Q. How do you change a door hose while the furnace is in operation?
A.
Never change a door hose unless the furnace is cooled. Please refer to the firebox door hose
section in the manual for further details or contact your local dealer.
Refer to:
• Firebox Door Hoses and Elbows (Located in Firebox and Other Components).
9.
Q. My furnace combustion blower continues to run but the fire will not burn until I open the
door?
A.
Your solenoid assembly is most likely not working to open the flipper. Please refer to the combustion
blower, solenoid and flipper section in the manual for further details or contact your local dealer.
Refer to:
• Combustion Air Blower, Solenoid and Flipper (Located in Air Supply).
10.
Q. Water is coming out of the chimney flue covers?
A.
Similar to the firebox, when your furnace is initially fired up and also at times during normal
operation, the atmosphere inside the firebox and chimney flue will exceed the dew point causing
condensation.
Refer to:
• Furnace has excessive moisture in firebox (Located in Trouble Shooting and Solutions)
• Dew Point (Located in Safe Operating Guidelines).
Summary of Contents for 400-4S
Page 1: ...Outdoor Furnaces TM SAVE THESE INSTRUCTIONS...
Page 10: ...5 HEATMOR Stainless Steel Outdoor Furnace Model 400 4S Chapter 1...
Page 73: ...68...
Page 88: ...83 PROBLEM CAUSE SOLUTION PROCEDURE...
Page 92: ...87 Outdoor Furnaces...
Page 93: ...88 NOTES...
Page 94: ...89 wiring diagram...
Page 95: ...90 Revised Manual on 07 11 12...