71
CHAPTER 26
TROUBLESHOOTING AND SOLUTIONS
Main Principles to Remember
♦
Enough Wood.
♦
Enough Water.
♦
Fans On – Air Must Get In.
♦
Fans Off – Air Must Stay Out.
♦
Water Temperature between 165 and 185 degrees Fahrenheit.
PROCEDURES ARE REFERENCED TO THIS HEATMOR™ “OPERATORS AND MAINTENANCE
MANUAL”
PROBLEM
CAUSE
SOLUTION
PROCEDURE
Furnace Boils
Solenoid not closing
flipper 100 percent.
Remove solenoid and
flipper assembly.
Clean, lube or replace.
Contact your
Local Dealer
.
Blower, Flipper Assembly
plate not tight.
Tighten wing nuts.
Refer to
Steps to
“Maintain your Blower
and Flipper Assembly.”
Firebox door ajar, not
shut tight.
Close Fire Door Tight.
Refer to
“Firebox Door.”
Ash cleanout tube not
sealed tight.
Close Tube Cover
Firmly.
Refer to
“Ash Cleanout Tube Cover
Plate.”
Flue cover plates not
sealed.
Tighten flue nuts.
Refer to
“Flue.”
Door gasket damaged.
Replace Gasket.
Refer to
“Firebox Door Gasket.”
Water Level is Low.
Add Water.
Refer to
“Filling the HEATMOR™
Outdoor Furnace Initially with
Water.”
Creosote buildup on
firebox doorframe
causing improper door
seal.
Remove creosote from
doorframe.
Refer to
“Firedoor Frame”
Summary of Contents for 400-4S
Page 1: ...Outdoor Furnaces TM SAVE THESE INSTRUCTIONS...
Page 10: ...5 HEATMOR Stainless Steel Outdoor Furnace Model 400 4S Chapter 1...
Page 73: ...68...
Page 88: ...83 PROBLEM CAUSE SOLUTION PROCEDURE...
Page 92: ...87 Outdoor Furnaces...
Page 93: ...88 NOTES...
Page 94: ...89 wiring diagram...
Page 95: ...90 Revised Manual on 07 11 12...