82
Water
temperature
doesn’t
correspond with
aquastat settings.
Inadequate rate of flow of
water allowing layering of
water temperatures.
Flow should be at
least eight gallons per
minute. Check pump
and installation.
Contact your
Local Dealer
.
No contact paste applied
to well of Temperature
Gauge.
Remove Temperature
Gauge from well and
apply paste.
Refer to
“Temperature Gauge.”
Faulty Water
Temperature Probe.
Replace Water
Temperature Probe
Refer to
“Water Temperature
Probe.”
PROBLEM
CAUSE
SOLUTION
PROCEDURE