background image

1

Updated: 07/10/12

TABLE OF CONTENTS

 

 

      

 

 

 

  

Page No.

Specifications            3 

Bladder             5 

Fire 

Door 

            6 

Air 

Supply 

            8 

 

Anti-Rollout 

Device 

and 

Ash 

Auger 

Tube 

        10

Supply 

Line 

and 

Return 

Line 

Threaded 

Connectors       11 

Low 

Water 

Cutoff 

           11

Outer 

Door 

            11 

Site 

Preparation 

Specifications 

         12 

Pad 

Specifications 

           13 

Wiring 

Diagram            14

 

Summary of Contents for 600 CSS

Page 1: ...ifications 3 Bladder 5 Fire Door 6 Air Supply 8 Anti Rollout Device and Ash Auger Tube 10 Supply Line and Return Line Threaded Connectors 11 Low Water Cutoff 11 Outer Door 11 Site Preparation Specific...

Page 2: ...AND MAINTENANCE MANUAL AND THIS SUPPLEMENT BEFORE OPERATING YOUR HEATMOR STAINLESS STEEL OUTDOOR FURNACE MODEL 600 CSS NOTE NEVER START A FIRE INSIDE THE FIREBOX UNTIL THE WATER JACKET IS FULL OF WATE...

Page 3: ...rebox height Inches 48 Volume of firebox Cu Ft 63 Firebox Door Size Inches 30 x 36 Flue transfer area Sq Ft 25 BTU S maximum 600 000 Water Jacket Steel Gauge Stainless 7 Firebox Steel Gauge Stainless...

Page 4: ...unit Limited LIFETIME Warranty Approvals Test Standards UL 2523 2009 CSA B366 1 11 Hookup Location Back Total Heat Extraction area sq ft 109 Type of Fuel WOOD ONLY Electrical Supply 1 Phase 115 Volts...

Page 5: ...rature is less than 100 F 38 C 1 Turn off the bladder gate valve located behind the top front access door 2 Remove the bladder cover plate by loosening the thumbnut and pulling out the plate 3 Loosen...

Page 6: ...assistance Opening the Fire Door It is important to always stand behind the fire door when opening it Open the door just slightly to allow air to the firebox This clears the firebox of smoke that may...

Page 7: ...tighter seal between the door seal gasket and doorframe Once the door has been adjusted to the correct depth the inner and outer nuts should once again be tightened against each other to hold the doo...

Page 8: ...ion where the furnace is overfilled with wood An over filled furnace will smoke more than one that has been properly filled with wood A properly filled furnace will have less problems with debris in t...

Page 9: ...required for optimal efficiency For example small pieces of wood high surface area with low moisture content requires a small amount of primary air and a large amount of secondary air If the opposite...

Page 10: ...r opening practices the risk of a flash back is greatly reduced Operation The A R D opens and closes automatically with the operation of the outer door Maintenance Result Ensure ash shavings or small...

Page 11: ...cated above the flue shuts down power to the fans when the water in the furnace is low The only way to restore power to the fans is to fill the furnace with water Do not fill a warm furnace with cold...

Page 12: ...12 Updated 07 10 12 Site Preparation Specifications Model 600...

Page 13: ...Pad Specifications Model 600 Notes 1 Pad sizes are shed base dimensions plus 3 inches in width and 2 inches in length 2 Pad thickness must be at least 4 inches but not more than 12 inches 3 All measur...

Reviews: