Updated: 07/10/12

Fire Door

Principles of the Fire Door

The Model 600 CSS fire door is water cooled to prevent warping of the 

door. It also absorbs heat from the fire and transfers heat to the water, 

adding a heat-exchanging surface. Because it is water cooled, the 

outer surface will never be hotter than the water in the furnace.

Removal and Replacement

If your fire door needs to be removed or replaced on your Model 600 

CSS, please contact your local dealer for assistance.

Opening the Fire Door

It is important to always stand behind the fire door when opening 

it. Open the door just slightly to allow air to the firebox. This clears 

the firebox of smoke that may be lingering in the firebox. Once the 

smoke is evacuated from the firebox it is safe to open the door fully, 

always standing behind the door for safety. Refer to the “Safe Furnace 

Operation Guidelines” section of the Operators and maintenance manual for further instruction on safe opening 

of the fire door.

 

 

 

 

 

 

 

Refer to Safe Operating Guidelines for further instructions on how to safely open and close the fire 

door or contact your local dealer.  Ask for a demonstration.

 

Summary of Contents for 600 CSS

Page 1: ...ifications 3 Bladder 5 Fire Door 6 Air Supply 8 Anti Rollout Device and Ash Auger Tube 10 Supply Line and Return Line Threaded Connectors 11 Low Water Cutoff 11 Outer Door 11 Site Preparation Specific...

Page 2: ...AND MAINTENANCE MANUAL AND THIS SUPPLEMENT BEFORE OPERATING YOUR HEATMOR STAINLESS STEEL OUTDOOR FURNACE MODEL 600 CSS NOTE NEVER START A FIRE INSIDE THE FIREBOX UNTIL THE WATER JACKET IS FULL OF WATE...

Page 3: ...rebox height Inches 48 Volume of firebox Cu Ft 63 Firebox Door Size Inches 30 x 36 Flue transfer area Sq Ft 25 BTU S maximum 600 000 Water Jacket Steel Gauge Stainless 7 Firebox Steel Gauge Stainless...

Page 4: ...unit Limited LIFETIME Warranty Approvals Test Standards UL 2523 2009 CSA B366 1 11 Hookup Location Back Total Heat Extraction area sq ft 109 Type of Fuel WOOD ONLY Electrical Supply 1 Phase 115 Volts...

Page 5: ...rature is less than 100 F 38 C 1 Turn off the bladder gate valve located behind the top front access door 2 Remove the bladder cover plate by loosening the thumbnut and pulling out the plate 3 Loosen...

Page 6: ...assistance Opening the Fire Door It is important to always stand behind the fire door when opening it Open the door just slightly to allow air to the firebox This clears the firebox of smoke that may...

Page 7: ...tighter seal between the door seal gasket and doorframe Once the door has been adjusted to the correct depth the inner and outer nuts should once again be tightened against each other to hold the doo...

Page 8: ...ion where the furnace is overfilled with wood An over filled furnace will smoke more than one that has been properly filled with wood A properly filled furnace will have less problems with debris in t...

Page 9: ...required for optimal efficiency For example small pieces of wood high surface area with low moisture content requires a small amount of primary air and a large amount of secondary air If the opposite...

Page 10: ...r opening practices the risk of a flash back is greatly reduced Operation The A R D opens and closes automatically with the operation of the outer door Maintenance Result Ensure ash shavings or small...

Page 11: ...cated above the flue shuts down power to the fans when the water in the furnace is low The only way to restore power to the fans is to fill the furnace with water Do not fill a warm furnace with cold...

Page 12: ...12 Updated 07 10 12 Site Preparation Specifications Model 600...

Page 13: ...Pad Specifications Model 600 Notes 1 Pad sizes are shed base dimensions plus 3 inches in width and 2 inches in length 2 Pad thickness must be at least 4 inches but not more than 12 inches 3 All measur...

Reviews: