72
chaPter 23
trOuBLeshOOtinG anD sOLutiOns
Main Principles to Remember
♦
Enough Wood.
♦
Enough Water.
♦
Fans On – Air Must Get In.
♦
Fans Off – Air Must Stay Out.
♦
Water Temperature between 145 and 185 degrees Fahrenheit.
PROCEDURES ARE REFERENCED TO HEATMOR™ “OPERATORS AND MAINTENANCE MANUAL”
WHICH COMES WITH EVERY NEW HEATMOR™ OUTDOOR WOOD FURNACE.
MANUALS ARE AVAILABLE SEPARATELY.
PrOBLeM
cause
sOLutiOn
PrOceDure
Furnace Boils
Draft flipper stuck open.
Remove blower and
flipper assembly.
Clean, lube or replace.
Refer to
Steps to
“Maintain your Blower
and Flipper assembly.”
Draft Flipper not closing
100 percent.
Remove blower and
flipper assembly.
Clean, lube or replace.
Refer to
Steps to
“Maintain your Blower
and Flipper assembly.”
Blower, Flipper Assembly
plate not tight.
Tighten wing nuts.
Refer to
Steps to
“Maintain your Blower
and Flipper assembly.”
Ashes holding flipper
open in air box(s).
Clean out ashes.
Refer to
“air Box(s).”
Firebox door improperly
adjusted.
Adjust Firebox Door.
Refer to
“Firebox Door.”
Firebox door ajar, not
shut tight.
Close Fire Door Tight.
Refer to
“Firebox Door.”
Ash Auger tube not
sealed tight.
Close Tube Cover
Firmly.
Refer to
“ash auger tube cover Plate.”
Top flue cover plate not
sealed.
Tighten ½ inch nuts.
Refer to
“top rectangular Flue.”
Door gasket damaged.
Replace Gasket.
Refer to
“Firebox Door Gasket.”