Figure 1.17 Showing how the water is heated as it passes through.
Page 5
SECTION TWO Siting and Plumbing
Spend some time planning exactly where to site the shower heater and riser rail.
Bear in mind the height of people who will be using it.
Tools you may need:
- Adjustable spanner giving at least 25 A/F
- Flat blade screwdriver with blade width 5-6mm
- No 2 Pozidriv screwdriver with a bit in good condition
- Sharp Stanley knife
- Round file
- Pipe cutters
- Electric drill and 7mm dia (N° 14) masonry bit
- Wire cutters
- Electrician's insulation strippers
Other items you may need:
- 15mm compression elbow or straight connector for connection to the shower unit
- 15mm isolating valve
Things you must do:
2.1
It is advisable to check that the water pressure to the shower is adequate. If in doubt, consult a competent
plumber.
Max: 1 MPa.
Min: Up to and including 9.5kW: 0.09 MPa Over 9.5kW: 0.11 MPa
21/03/2011
www.partsarena.co.uk/baxi/System/DA…
partsarena.co.uk/baxi/…/I47-2835.htm