background image

1

SUPREME 140, 155, 170

Fitting Instructions and User Guide

FULL

HALF FULL

TEMPERATURE

READY

ON

Summary of Contents for SUPREME 140

Page 1: ...1 SUPREME 140 155 170 Fitting Instructions and User Guide FULL HALF FULL TEMPERATURE READY ON...

Page 2: ...tres Weight full Model 140 8 4 kg Model 155 11 8 kg Model 170 15 4 kg Rated pressure 0 bar Minimum supply pressure 0 5 bar 7 p s i Maximum supply pressure 10 bar 145 p s i Nominal commissioning times...

Page 3: ...n The vent pipe material must be capable of conveying boiling water The vent pipe must never be connected directly to a soil pipe 1 3 Wherever possible the Supreme should be supplied directly from a r...

Page 4: ...er A drip tray is available as an accessory Heatrae Sadia Code No 95 970 123 The heater should be positioned at such a level that suitable tea coffee etc making utensils can be placed under the outlet...

Page 5: ...Drill and plug the fixing positions Fix the mounting bracket to the wall using the two No 12 x 2 screws provided 2 6 If rear entry services are to be used the necessary holes for these should be prep...

Page 6: ...to allow either bottom or rear entry of services If a combination of entry points are required an additional connector will be required as follows Bottom inlet rear vent Push Fit 15mm x 15mm elbow Hea...

Page 7: ...of the cable must be secured using the cable clamp provided It is not necessary to clamp a rear cable entry 5 4 Connect the cable to the terminal block as follows BROWN or RED wire to terminal marked...

Page 8: ...unit is in its self commissioning mode After a while the HALF FULL indicator will illuminate to indicate the unit is half full of water After a further period the FULL indicator will illuminate to ind...

Page 9: ...t and solenoid valve 7 3 The Supreme incorporates an electronic scale conditioning function which will reduce the rate of scale deposition in hard water areas However in extreme circumstances some dep...

Page 10: ...lt 1 Check electrical supply to unit and that primary cutout has not operated 2 Check water supply 3 Check operation of solenoid valve replace if necessary Unit does not heat on commissioning 1 If ON...

Page 11: ...ns to electronic control Replace if necessary Steam from vent pipe and primary cutout operates 1 Control thermistor fault 2 Electronic control fault 3 Scale build up 1 Check continuity of thermistor 2...

Page 12: ...bly 95 605 877 Solenoid valve coil 95 605 839 Level sensor 95 612 692 Electronics assembly 95 615 043 Indicator board 95 615 039 Primary cutout 95 612 693 Wiring harness complete 95 612 694 Wiring har...

Page 13: ...95 611 817 Steam condenser sealing gasket 155 model 95 611 819 Steam condenser sealing gasket 170 model 95 611 820 O ring kit 95 611 818 Push fit connector 15mm x 15mm straight 95 607 509 Push fit co...

Page 14: ...he electrical supply to the Supreme is switched on TEMPERATURE READY When illuminated indicates that the stored water is hot enough to use HALF FULL When illuminated indicates that the unit is at leas...

Page 15: ...y for a short while If this condition occurs it is recommended that the first few cups are drawn off and discarded Guarantee This Supreme water heater is guaranteed for a period of two years from the...

Page 16: ...Lancashire PR5 1JX Tel 01772 819673 www hrpc co uk Newey Eyre Specialists Products Division Please contact your local branch UK Spares Ltd Tower Lane Warmley Bristol BS30 8XT Tel 0117 961 6670 William...

Reviews: