7.0 MAINTENANCE

NOTE: It is recommended that any maintenance be carried out by
competent persons.  Disconnect the electrical supply before
removing the cover.

Maintenance instructions are available from the Heatrae Sadia
Service Department.  Telephone 08701 600125 , Fax 08701 600181

7.1 The electronic control system of the Supreme has a self-

diagnostic feature which determines if the unit is operating
satisfactorily.  If it is not operating correctly the nature of the fault
is ascertained and a fault mode is indicated.

7.2 If steam or boiling water discharges from the vent pipe the

Supreme will switch off.  Other critical faults are indicated by the
indicators flashing.  The cause of the fault will be indicated by
which is flashing (see Section 8.0 FAULT FINDING).  A critical
fault would render the unit unsafe to use and so will deactivate
both the element and solenoid valve.

7.3 The Supreme incorporates an electronic scale conditioning

function which will reduce the rate of scale deposition in hard
water areas.  However, in extreme circumstances some deposits
may still occur in the storage tank, these should be periodically
removed.

Supreme Maintenance Plan

Heatrae Sadia are pleased to offer a preventative maintenance
program to ensure that your product will continue to operate to your
satisfaction in even the most troublesome of water conditions.
The service provided includes an inspection, descale and functional
test, scheduled to meet your requirements.    All work under the plan
will be carried out by one of our authorised service engineers, who
are fully trained, regularly audited and carry a complete stock of spare
parts.  This plan is in addition to the manufacturer’s warranty and
does not cover the cost of materials associated with any out of
warranty component repairs.
For further information on the Maintenance Plan please contact our
Service Department. Telephone 08701 600125, Fax 08701 600181.

Summary of Contents for SUPREME 140

Page 1: ...1 SUPREME 140 155 170 Fitting Instructions and User Guide FULL HALF FULL TEMPERATURE READY ON...

Page 2: ...tres Weight full Model 140 8 4 kg Model 155 11 8 kg Model 170 15 4 kg Rated pressure 0 bar Minimum supply pressure 0 5 bar 7 p s i Maximum supply pressure 10 bar 145 p s i Nominal commissioning times...

Page 3: ...n The vent pipe material must be capable of conveying boiling water The vent pipe must never be connected directly to a soil pipe 1 3 Wherever possible the Supreme should be supplied directly from a r...

Page 4: ...er A drip tray is available as an accessory Heatrae Sadia Code No 95 970 123 The heater should be positioned at such a level that suitable tea coffee etc making utensils can be placed under the outlet...

Page 5: ...Drill and plug the fixing positions Fix the mounting bracket to the wall using the two No 12 x 2 screws provided 2 6 If rear entry services are to be used the necessary holes for these should be prep...

Page 6: ...to allow either bottom or rear entry of services If a combination of entry points are required an additional connector will be required as follows Bottom inlet rear vent Push Fit 15mm x 15mm elbow Hea...

Page 7: ...of the cable must be secured using the cable clamp provided It is not necessary to clamp a rear cable entry 5 4 Connect the cable to the terminal block as follows BROWN or RED wire to terminal marked...

Page 8: ...unit is in its self commissioning mode After a while the HALF FULL indicator will illuminate to indicate the unit is half full of water After a further period the FULL indicator will illuminate to ind...

Page 9: ...t and solenoid valve 7 3 The Supreme incorporates an electronic scale conditioning function which will reduce the rate of scale deposition in hard water areas However in extreme circumstances some dep...

Page 10: ...lt 1 Check electrical supply to unit and that primary cutout has not operated 2 Check water supply 3 Check operation of solenoid valve replace if necessary Unit does not heat on commissioning 1 If ON...

Page 11: ...ns to electronic control Replace if necessary Steam from vent pipe and primary cutout operates 1 Control thermistor fault 2 Electronic control fault 3 Scale build up 1 Check continuity of thermistor 2...

Page 12: ...bly 95 605 877 Solenoid valve coil 95 605 839 Level sensor 95 612 692 Electronics assembly 95 615 043 Indicator board 95 615 039 Primary cutout 95 612 693 Wiring harness complete 95 612 694 Wiring har...

Page 13: ...95 611 817 Steam condenser sealing gasket 155 model 95 611 819 Steam condenser sealing gasket 170 model 95 611 820 O ring kit 95 611 818 Push fit connector 15mm x 15mm straight 95 607 509 Push fit co...

Page 14: ...he electrical supply to the Supreme is switched on TEMPERATURE READY When illuminated indicates that the stored water is hot enough to use HALF FULL When illuminated indicates that the unit is at leas...

Page 15: ...y for a short while If this condition occurs it is recommended that the first few cups are drawn off and discarded Guarantee This Supreme water heater is guaranteed for a period of two years from the...

Page 16: ...Lancashire PR5 1JX Tel 01772 819673 www hrpc co uk Newey Eyre Specialists Products Division Please contact your local branch UK Spares Ltd Tower Lane Warmley Bristol BS30 8XT Tel 0117 961 6670 William...

Reviews: