background image

HeatSeeker Swimming Pool Heat Pump: Page 3 of 10 

A. Positioning Your Swimming Pool Heat Pump 

1.  For correct operation air must be free to circulate around the heat pump. Do not place 

the unit in a shed, greenhouse or similar. This unit is designed to be placed outdoors 
only. 

2.  Ensure there is at least 1000mm (1.0m) of clearance all around each side of the heat 

pump to allow air circulation and access for maintenance. 

3.  Do not block the top air exit where the fan expels air upwards from the unit. There must 

be no obstruction above this air exit for at least 2000mm (2.0m). 

4.  You should position the heat pump so that the control panel does not face directly 

towards the sun.  

5.  The heat pump must be upright. 
6.  The distance between the heat pump and the pool / plant room should be as short as 

practically possible to reduce pressure and heat loss in the pipe work. 

7.  Insulating the pipe work will assist with the prevention of heat losses. 
8.  An isolator switch should be installed (by a qualified electrician)

 

near the heat pump. 

9.  The electrical supply to the heat pump must be protected by a 30mA RCD. 
10. The air inlets and outlets must not be obstructed or blocked. 
11. Even though the heat pump is low noise, it must be positioned so as to be considerate 

to neighbours. 

12. Your heat pump must be placed on a solid base.  
13. Condensation will drip from underneath the heat pump, your base must be able to 

tolerate this. 

 

B. Connecting Your Swimming Pool Pipe Work 

1.  The pool water is fed through the heat pump by a swimming pool pump. 
2.  The heat pump must be installed after (down stream) the swimming pool filter so clean, 

filtered water passes through it. 

3.  Double union ball valves must be fitted just before the heat pump inlet and just after the 

outlet to aid servicing and winterising. 

4.  Each heat pump has a maximum water flow rate. If the flow via the pool pump is higher 

than this then a by-pass should be installed. Consult your supplying dealer. 

5.  Each heat pump also has a minimum flow rate, below this the heat pump will not 

operate. Consult your supplying dealer. 

6.  Pipe work of less than 1½" diameter should not be used. 
7.  Fit a union nut onto each pipe. 
8.  Push the gasket over the pipe until the gasket is about 5 -10mm from the edge of the 

pipe. You may need to lubricate the gasket. 

9.  Insert the pipe into the heat pump and tighten the union nut. 
10. The union must only

 

be hand tightened. 

11. If the swimming pool is equipped with a chlorinator, brominator, or possibly chemical 

control with acid and chlorine pumps, these must

 

be in the return pipe work after the 

heat pump and a non-return valve used. Any dosing system must be the final 
equipment before the water returns to the swimming pool. Damage caused to the heat 
pump by chemical dosing units is not covered by warranty. 

12. Any heat exchanger or electric heater fitted as auxiliary heating must be installed after 

(down stream from) the heat pump so as to avoid pre-heating the pool water before it 
enters the heat pump.

 

 

 

Summary of Contents for WBR-17.0H-A

Page 1: ...ompressor and a 5 year parts warranty on the titanium heat exchanger Please contact your supplying dealer in the event of a claim This heat pump is designed for domestic use between May and September...

Page 2: ...Connecting Pipe Work C Sizes D Starting the Heat Pump E Setting the Temperature F Checking the Status G Changing the Mode H Auxiliary Mode I Winterising and Maintenance J Troubleshooting Error Codes K...

Page 3: ...be able to tolerate this B Connecting Your Swimming Pool Pipe Work 1 The pool water is fed through the heat pump by a swimming pool pump 2 The heat pump must be installed after down stream the swimmin...

Page 4: ...HeatSeeker Swimming Pool Heat Pump Page 4 of 10 C Sizes of Your Swimming Pool Heat Pump WBR 17 0H A WBR 21 0H A S A 855 955 B 660 660 C 660 660 F 370 370 G 110 110...

Page 5: ...de Set Aux 3 After a few seconds the display shows ROOM and a temperature This is the temperature of the air surrounding the heat pump 4 Push the START STOP button and await the display to show the in...

Page 6: ...to the standby mode after a few seconds 5 Restart the heat pump by pressing the START STOP button 6 After the 2 3 minute delay the heat pump will re start with the new set temperature F Checking the...

Page 7: ...ection H Auxiliary Mode of Your Swimming Pool Heat Pump 1 The AUX button on the heat pump is not used 2 When pressed the AUX button may make a wavy line symbol appear and disappear on the display but...

Page 8: ...sensor fault error PP 01 Sensor interrupted or short circuited Test line sensor and socket May have to be replaced Water temperature out sensor fault error PP 02 Sensor interrupted or short circuited...

Page 9: ...1 Heating only 3 0 3 3 For technician only 09 Work method 0 0 May not be changed 10 Setting of water temp auto mode 30 C 30 C For technician only 5 With the exception of Parameter 01 setting the pool...

Page 10: ...roll Number of Fans 1 Input Power of Fan W 200 200 Fan Rotation Speed rpm 830 830 Noise Level dB 60 60 Water Connection inches 1 1 Water Flow Rate m 3 h 5 8 6 10 Water Pressure Drop KPa 16 16 Unit Dim...