HeatSeeker Swimming Pool Heat Pump: Page 8 of 10
J. Troubleshooting Your Swimming Pool Heat Pump: Error Codes
1. The most common problem reported is the heat pump showing a display but not
running its fan and compressor. This is the time delay on start up. From pressing
START/STOP there is a 2 – 3 minute delay before the fan and compressor start.
2. The second most common problem is insufficient flow through the heat pump indicated
by EE 03. If your swimming pool filter has a multiport valve turn off the pool pump and
turn the valve to “recirculate” , restart the pool pump and try the heat pump again. If this
solves the problem make sure your sand filter is backwashed.
3. Another issue is not being able to operate the control panel at all. Look for a small
padlock symbol on the display which means that the controls are locked. To release
this press the up and down arrows together at the same time for about 5 seconds so
that the padlock symbol disappears.
4. During the operating and defrosting process, the heat pump will yield a volume of
condensed water. The condensed water from the cooling coil will drip from the bottom
of the heat pump. Do not assume the condensed water is due to a fault or a leak in the
heat pump.
The table below shows error codes the heat pump may display
Fault/Error
Display
Cause
Action
Water temperature
in, sensor fault/error
PP 01
Sensor interrupted or short circuited
Test line, sensor and
socket.
May have to be replaced
Water temperature
out, sensor
fault/error
PP 02
Sensor interrupted or short circuited
Test line, sensor and
socket.
May have to be replaced
Coil 1 sensor
fault/error
PP 03
Sensor interrupted or short circuited
Test line, sensor and
socket.
May have to be replaced
Coil 2 sensor
fault/error
PP 04
Sensor interrupted or short circuited
Test line, sensor and
socket.
May have to be replaced
Ambient temperature
sensor
PP 05
Sensor interrupted or short circuited
Test line, sensor and
socket.
May have to be replaced
Too high difference
in
temperature in/out.
PP 06
Water flow too low
Check valves, filter pump,
filter and by-pass
Heating up
PP 07
Water flow too low
Check valves, filter pump,
filter and by-pass
First frost proofing
run
PP 08
Low out temperature
Empty system of water
Second frost
proofing run
PP 09
Low out temperature
Empty system of water
Function error in
system 1
EE 01
Function error in print card
Call technician
Function error in
system 2
EE 02
Input voltage too low
Check main cable /
electrician
Flow guard error
EE 03
Too small or too high flow
Check pool pump, piping,
by-pass and ball cocks.
Check technical spec
EE 04
Temperature
fluctuations
EE 05
Water flow varying
Check pool pump and
piping. Check valves, filter
and by-pass
Defrosting
Logo
Cold coil / element.
None. Normal function
Communication error
EE 08
Communication error between
control panel and control
Check cable connection.
Call technician