background image

Having decided on the location of the heater it is necessary to drill 2 fixing holes
8mm diameter by 43mm deep at 417mm centres on a horizontal line at a minimum
height of 400mm from the floor. Allowance must be made for the final floor
covering, carpet etc, and if any skirting boards are present, the fixing holes must be
a minimum of 400mm above the top edge of the skirting board. Using the plastic
plugs and fixing screws provided, attach 2 of the fixing brackets to the wall. The
other pair of fixing brackets must be attached to the base of the heater using the feet
retaining screws so that the brackets project out at the rear of the heater and space
the bottom edge away from the wall.

If required, these brackets may also be secured to the wall using the remaining
fixing screws and plastic wall plugs. If this option is chosen it is suggested that the
heater is hung on the upper brackets and the hole positions for the lower brackets is
then marked on the wall, prior to drilling the holes for attachment purposes.

Operation of the heater 

NOTE:  

It is normal when the heaters are turned on

for the first time or when they are turned on after
having not been used for a long period of time the
heaters may emit some smell and fumes.  This will
disappear when the heater has been on a short while.

HS2020XCN Convector heater with 
switches and thermostat 

Choose a suitable location for the heater, taking into
account the safety instructions above.  

Insert the plug of the heater into a suitable socket.

Turn the thermostat knob (

in figure 2) 

fully in a

clockwise direction to the maximum setting.

Turn on the heating elements by means of the rocker
switches on the side panel (

in figure 2)

.  When the

heating elements are on the switches will illuminate. For
maximum heat output both switches should be on.

When the desired room temperature has been reached, the thermostat knob should
be turned slowly anti-clockwise until the thermostat is heard to click off and the lights
on the element switches are seen to go out. After this the heater will keep the air
temperature in the room at the set temperature by switching on and off
automatically.    

In its minimum (fully anti-clockwise) position, the thermostat provides a frost guard
position. In this position (depending on the size of the room) the heater will maintain
the temperature above freezing.

Model covered by these instructions:

HS2020XCN

– Convector heater with switches and thermostat

SPECIFICATION 

– 1800-2000W; 230-240V; 50Hz;

Safety Instructions 

DO NOT use the heater unless the feet are correctly attached.

ALWAYS ensure that the heater is placed on a firm level surface. Ensure that the
heater is not positioned close to curtains or furniture as this could create a fire
hazard. 

MAKE SURE the power supply to the socket into which the heater is plugged is in
accordance with the rating label on the heater and that the socket is earthed.

KEEP the power cord away from the hot body of the heater. 

DO NOT use the heater if the power cord is damaged, it must be replaced by a
recognised service agent or a similarly qualified person.

DO NOT position the heater in front of, or immediately below a wall socket.

ALWAYS unplug the heater when moving it from one location to another.

The heater is for indoor use only.

The heater is not intended for use in bathrooms, laundry areas or similar indoor
locations. Never place the heater where it may fall into a bath or other water
container.

DO NOT use the heater in areas where flammable liquids are stored or where
flammable fumes may be present.

DO NOT place the heater on carpets having a very deep pile.                              

DO NOT insert any object through the heat outlet or air grilles of the heater.

WARNING: In order to avoid overheating, do not cover the heater.

Assembly and installation

Before using the heater, the feet (supplied separately in
the carton) must be fitted to the unit.  These are to be
attached to the base of the heater using the 4 self-
tapping screws provided, taking care to ensure that they
are located correctly in the bottom ends of the heater
side mouldings (

see Figure 1

).

Wall-mounting 

The heater is supplied with 4 sets of fixing brackets,
screws and plastic wall plugs to enable it to be mounted onto a wall if required. If it
is decided to fit the heater to a wall the feet must be removed.

It must not be positioned in-front of, below a power socket, a shelf, curtains or any
other obstruction. Please refer to the safety instructions.

Figure 1

Figure 2


HS2020XCN[10]instructions  20/7/10  16:47  Page 3

Reviews: