Usage and product description

The air curtain is designed to prevent the entry of the cold ambient air into

a building and to reduce the thermal losses inside the premises. The

curtain is designed for the operation in premises with the ambient

temperature of  from -10°C to +40°C and the relative humidity up to 80%

(at the tempe25°C).

The HSAC3 is manufactured from sheet steel coated with a high-quality

polymer. The ‘body’ of the unit contains heating elements, the fan modules

and the control switches. The fans draw in the air through the front

perforated grid of the body (2); the airflow passing through the heating

elements is heated, enters the ventilation assembly and released through

the air-relief nozzle (3) as the directed flow.

The HSAC3 also has a cool air circulation function in addition to ‘full’ and

’half’ power heating functions.

Before Installation

Select a suitable position for installation, allowing free access all around

and no closer than 100mm to the ceiling. For wide doorways, these units

may be mounted end-to-end, but allowing a suitable gap for the mounting

brackets if these are used, and for access and cable entry.

Installation

The HSAC3 may be fixed directly to the surface above an entry or for

greater operational flexibility may be installed using the supplied mounting

brackets. 

See overleaf for details

.

Model covered by these instructions:

HSAC3

– 3kW Air Curtain with ‘half-power’ setting and air circulation

mode

Safety Instructions 

• Please read these installation and operating

instructions before using the product. Failure to do so
may cause injury or void the warranty.

• This Air Curtain is NOT suitable for installation in a

hostile environment.

• DO NOT operate the heat curtain in premises with

the relative humidity >80%.

• The heater MUST be earthed when installed.

• DO NOT switch on the heater if the covers are

removed.

• If the curtain is connected directly to the fixed wiring it

must be provided with an automatic circuit breaker or
tripping device.

• ALWAYS conform to the general safety rules for

electrical devices.

• DO NOT cover the unit and do not limit the air flow

at the inlet and outlet, 

• DO NOT operate the unit if there is visible damage to

the unit or power supply.

• Only a suitable qualified person should install and

maintain the unit, otherwise there may be a risk of,
electric shock or fire.

• To avoid electric shock disconnect the device from the

power mains before starting cleaning or maintaining.

3

2

Figure 1

Dimensions

L = 

585mm

A =

450mm

B = 

65mm

C =

30mm

E =

155mm

F =

150mm

HSAC3[16]instructions  9/6/16  09:18  Page 2

Summary of Contents for HSAC3

Page 1: ...RDS WHEN USING ANY ELECTRICAL APPLIANCE BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED PLEASE READ ALL INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE ISSUE 1 0616 HSAC3 Air Curtain Operating Instructions 3kW Air Curtain with half power setting and air circulation mode HSAC3 16 instructions 9 6 16 09 18 Page 1 ...

Page 2: ...ed directly to the surface above an entry or for greater operational flexibility may be installed using the supplied mounting brackets See overleaf for details Model covered by these instructions HSAC3 3kW Air Curtain with half power setting and air circulation mode Safety Instructions Please read these installation and operating instructions before using the product Failure to do so may cause inj...

Page 3: ...culation 1 2 Power on and half power heating 1 2 3 Power on and full power heating Installing directly on the wall The unit has two slots on its back panel allowing the unit to be directly mounted to a wall see figure 1 on page 3 Make sure enough space is available for the supply cable entry to the unit Installing using the adjustable brackets supplied Remove mounting bracket screws allowing the m...

Page 4: ...pplied to the motor bearing from time to time Troubleshooting If you are in any doubt about the installation operation or maintenance of this unit please contact the Heatstore Technical team on 0117 923 5375 7 6 Power Output Full Power kW 3 Power Output Half Power kW 1 5 Power Output Ventilation mode W 70 Current A 16 Supply Voltage V Hz 230 50 Air Capacity m3 hr 350 Electrical Protection CLASS 1 ...

Reviews: