background image

 
 

                                      

OPERATION, INSTALLATION AND MAINTENANCE MANUAL 

Fl us h Mount   Enc l osur e  

f or 

He a tst ri p  El e ga nc e  

( THE  Ra nge )  

Summary of Contents for THE 1800

Page 1: ...OPERATION INSTALLATION AND MAINTENANCE MANUAL Flush Mount Enclosure for Heatstrip Elegance THE Range ...

Page 2: ...eatly install the HEATSTRIP into a ceiling They are available for all HEATSTRIP Elegance models and are supplied as a one piece unit suitable for mounting individual heaters Flush mounting can be used with any building grade ceiling materials An ideal mounting height is 2 3m 2 5m with a maximum ceiling height of 2 7m in a fully enclosed outdoor environ ment Maximum mounting heights should be stric...

Page 3: ...3 Flush Mount Enclosure Dimensions PART No MODEL A mm B mm C mm THEAC 040 THE1800 1080 1024 1020 THEAC 041 THE2400 1310 1254 1250 THEAC 042 THE3600 1910 1854 1850 VIEW FROM UNDERNEATH VIEW FROM TOP ...

Page 4: ...Enclosure The enclosure has a number of openings for ventilation and air movement into the ceiling space these openings must not be covered The enclosure shall under no circum stances be covered with insulating material or similar material It is recommended to use only the provided holes in the ends of the enclosure for mounting Ensure all clearances detailed in the HEATSTRIP ELEGANCE PRODUCT MANU...

Page 5: ... only the provided holes in the ends of the enclosure for mounting The minimum distance between the back of the enclosure and any building material is 150mm The minimum distance between the sides of the enclosure and any support structure is 50mm The minimum distance between adjacent enclosures is 200mm VIEW FROM BELOW Ceiling removed VIEW FROM SIDE ...

Page 6: ...he spacing of the brackets are listed in the table STEP 2 Screw the FME into the battens NOTE screws are not included STEP 3 If there is no roof ac cess connect the heater to the power source ensure the power is OFF STEP 4 Lift the heater into the FME ensuring the brackets are to the side of the mounting cut outs STEP 5 Push the heater to the left ensuring the brackets engage in the mounting hole ...

Page 7: ...m durable materials however regular care and maintenance of your product will help prolong its life It is recommended that you wipe down your Flush Mount Enclosure With a soft cloth and mild deter gent gently wipe the surfaces of the FME to remove the built up contaminants from the environment Then with a clean cloth ensure all detergent is removed All chemicals in the atmosphere including cigaret...

Page 8: ...ty product or components by Thermofilm or an authorized representative of Thermofilm Thermofilm does not participate in any site related costs or labour expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of parts to complete products and assumes no liability on parts repaired or replaced without written authorisation Thermofilm shall not ...

Reviews: