8
Selection guide
General recommendations for
HEATSTRIP
®
Elegance:
Ideal mounting height: 2.3m to 2.5m. Maximum is 2.7m in a fully protected/enclosed outdoor environment.
Ideal mounting location: ceiling mounted, directly above area to be heated (eg. above a table)
Minimum recommended heating capacity for various installations are: 400W/m
2
for indoor spot heating; 500W/m
2
for protected outdoor areas, and 600W/m
2
for exposed outdoor areas. To ensure the HEATSTRIP
®
Elegance pro-
vides satisfactory performance, Thermofilm strongly recommends using conservative coverage areas when speci-
fying how many heaters are required for each installation.
The table below outlines the
maximum
coverage of each
HEATSTRIP
®
Elegance
model based on 3 different scenarios
with direct overhead mounting at minimum installation height. For example, for an outdoor area that is protected from pre-
vailing winds by walls, café blinds etc, Model THE1800 will cover a
maximum
of 3.6m
2
and Model THE2400 will cover a
maximum
of 4.8m
2
.
For angled wall mounting applications, the coverage is reduced by up to 40%.
MODEL
INDOOR PROTECTED (m
2
) OUTDOOR ENCLOSED (m
2
)
OUTDOOR EXPOSED (m
2
)
THE 1800
4.5
3.6
3
THE 2400
6
4.8
4
THE 3600
9
7.2
6