Setting the Program Schedules
This thermostat has the ability to program each individual day of the week separately, or program 7 days of the week at once. You can also program weekdays
Set to the time you would like to wake to and the temperature y ou want during the morning, until you left for the day.
Press and the day display will start flashing. (If your thermostat is set to 5+2 day programmable mode, the p rogramming will skip to step3)
Use to adjust the day of the week you want to start programming or to the day you wish to edit an existin g event / program.
(Press to select all 7 days of the week, and to cancel press again.)
Press
Use and to adjust the time you wish the Program 1 event to commence for the selected day/days .
Press
and the temperature will start flashing.
Use and to set the desired tem perature to be maintained during Program 1.
Press and the LCD screen will show Program 2 with the time display flashing, this signifies that the second daily event is now ready to be programmed.
Repeat steps 4,5,6 to set the remaining programs/events, then p ress to store and exit.
Hint: During setting programs, press will clear a program entry and thermostat will maintain the temperature s etpoint of the last executed program
Above are default program schedules, to make changes, first press and then follow the below steps,
Set to the time you leave home and the temperature you wish you r home to maintain while you are away at work perhaps.
Set to the time you return home at end of the day and the tempe rature you want during evening until bed time.
Set to the time you sleep and the temperature you want overnigh t(usually a comfortable and energy saving temperature).
07:00
1
2
3
4
22 °C
16:30 22 °C
09:30 16 °C
22:30
1.
2.
3.
4.
5.
6.
7.
16 °C
WAKE
Program Start Time Setpoint
Explanation
LEAVE
RETURN
SLEEP
the LCD screen will show Program 1( ) and the time will be flashing.
Page 2
This product should be installed by
a qualified electrician.
Installation and Wiring
Carefully separate the front half of the thermostat from the ba ck plate by placing a small
flat head terminal driver into the slots on the bottom face of the thermostat.
Carefully unplug the ribbon connector which is plugged in to th e front half of the thermostat.
Place the thermostat front half somewhere safe. Terminate the t hermostat as shown in
the diagrams below.
Screw the thermostat back plate on to the flush box
Re-connect the thermostat ribbon cable and clip the two halves together.
Thermos t at I nstructions
ver 1.0
until the beginning of the next program( only for program 2 and 3 on Saturday and Sunday).
NEXT
NEXT
NEXT
DONE
DONE
DELETE
SCHEDULE
SETUP
SETUP
DAY
DAY
Temporary Temperature Override (Auto mode only)
Touch the temperature display, and it will start to flash. Use up or down
buttons to adjust. Press to accept, and you will s ee “Override”
above the temperature display. Thermostat will maintain the n ew set
Lock the Keypad
To lock the keypad, press and hold the top left corner of display for 5 seconds,
you will see a lock symbol . To unlock, repeat the steps ab ove and the
Reset to Factory Setting
With thermostat turned off, press and hold the middle area of the screen
for 5 seconds until you can
DONE
RUN
SCHEDULE
see -- : -- on LCD.
temperature until the next programmed event(comfort level). To cancel
the override setting, press
Auto / Manual Mode
Holiday Function
MODE
HOLIDAY
Press to select Auto/Manual mode. In Manual mode( ), the
thermostat maintains
a constant set temperature manually set by the user.
In Auto mode, the thermostat executes the preprogrammed schedul es.
Press , enter the duration of your holiday by
Press ,
or .
Press . To cancel a Holiday,reduce the holiday per iod to 00 days.
The Holiday function reduces the temperature in your room to th e frost protection
temperature. The thermostat will maintain this temperature for the duration of the
holiday and will then automatically return to the program mode on your return.
(5 days) to one schedule and then weekends (2 days) to a diffe rent schedule. See the Menu information for details on how to set this up.(refer to Menu 5)
lock symbol will disappear.
TR8100VHO