| 11
that could then drip onto the heater.
•
DO NOT install above electrical boxes or junctions.
•
Your water heater must be located in an area where leakage from the unit or the connections will not
result in damage to the area adjacent to the water heater or to lower floors of the structure. Where such
areas cannot be avoided, it is recommended a suitable catch pan that is connected to an adequate drain,
be installed under the water heater. Make sure to follow all code requirements for such installations as
required for your area.
•
Alternatively, you could install an active water leak detector and shutoff valve designed to turn off your
water supply if a leak is detected.
MOUNTING
Your tankless water heater should be secured to the mounting surface using the mounting bracket with two (2)
pre-installed mounting bracket screws. ONLY mount heater in a vertical position with the water fittings located
on the bottom of the heater.
RECOMMENDED MINIMUM CLEARANCES
•
12” (305 mm) above and below the heater
•
12” (305 mm) in front of and to the sides of the heater
Flammable materials should be kept at least 24” (610 mm) away from your water heater and the hot
water outlet pipe.
See measurements of the MODEL 3 unit on the next page.
CORRECT
INCORRECT
INCORRECT