13 

www.hedefsan.net 

01 Ocak 2015 

 

 

 

 

 

 

Card fixing hole 

LCD Display 

Setting buttons 

Mika hole 

157 mm 

181 mm 

150 m

m

 

123 m

m

 

150 mm 

27m

m

 

22

 mm

 

Mika 

Mika extension screw 

Main controller 

 

Summary of Contents for HD Eko 10

Page 1: ...1 www hedefsan net 01 Ocak 2015 Small in size with grand features USER GUIDE Elle m me petite mais avec caract ristique grand...

Page 2: ...Phase Level 11 Ptc 12 Contact Feedback 13 Position reset 14 Limit Switch 15 Digital Setting 16 Display Exit 17 Max Car Call Registration 18 Number of Basement 19 Fire Stop 20 Park Stop 21 Return to Pa...

Page 3: ...tors in emergency descent 24Vdc Control Signal Inputs 24 5 Vdc Control Signal Outputs 24 5 Vdc Short Circuit Protection MAJOR FEATURES 2 line 16 character LCD display and 4 button keyboard RS 485 seri...

Page 4: ...e connected parallely No other except the one registration is kept in memory Mixed Collective The cabin and floor buttons are connected parallely Registrations are kept in memory Down Collective The c...

Page 5: ...l Aut limited Only used for elevators with full automatic limited cabin doors According to the EN 81 1 2 standarts in states of emergency stop revision and take back automatic doors must remain statio...

Page 6: ...OWN buttons A B NUMBER OF STOP 07 Number of Stops D 10 Set the number of stops maximum 10 here CABIN SERIAL CARD 08 Cabin Serial Card 19200 Baud Set the communication speed between the main controller...

Page 7: ...r card will remember its last position But in some special cases when the power returns a position reset may be wanted In that case the elevator will go until it reaches the 817 limit switch of the bo...

Page 8: ...5 6 7 8 9 10 11 12 13 14 15 16 A B C D E F H J L N O P DISPLAY OUTPUT 16 Display Output Normal Set the display output of the HD EKO 10 controller card and HD EKO SERI card 7 Segment output Normal out...

Page 9: ...e park stop here When elevator pauses its operation it goes to this floor and waits with open doors RETURN TO PARK 21 Return to park 200 Seconds Set the waiting time before going to park stop 0 250 Se...

Page 10: ...onds OPEN DOOR TIME 24 Open Door Time 15 Seconds Set the time from opening till the start of closing of the automatic door 05 20 Seconds Set the door open close time between the minimum and maximum LO...

Page 11: ...ce 10 seconds If longest cruising distance is less than 10 seconds the timeout should be at least 20 seconds SLOW CRUISING 29 Slow Cruising 015 Seconds Set the maximum time of slow cruising from the m...

Page 12: ...is set for 45 days this parameter will show a value of 15 when 30 days have passed After 45 days the value will be 0 45 250 Days Set the maintenance time between the minimum and maximum CHANGE PASSWOR...

Page 13: ...13 www hedefsan net 01 Ocak 2015 Card fixing hole LCD Display Setting buttons Mika hole 157 mm 181 mm 150 mm 123 mm 150 mm 27mm 22 mm Mika Mika extension screw Main controller...