H E D L E R S y s t e m l i c h t G m b H H e e r s t r a s s e 1 1 2 D - 6 5 5 9 4 R u n k e l / L a h n w w w . h e d l e r. c o m
Te l e f o n + 4 9 - ( 0 ) 6 4 8 2 9 1 8 1 0 0 Te l e f a x + 4 9 - ( 0 ) 6 4 8 2 9 1 8 1 1 1 e M a i l i n f o @ h e d l e r. c o m
Profilux
®
LED
1400
/ Profilux
®
LED
1400
DMX
TECHNICAL DATA Profilux
®
LED
1400
Type: Profilux
®
LED
1400
Voltage: 110 - 230 V ~ 1,0A 50/60 Hz
Power: 185 W LED
Risk group: 0-RG
Color: CRI > 95
Kelvin: 5600K
Safety class system: I
Protection category: IP30
Weight: 3600g
Ambient temperature (Ta): -15° - +40° C
Surface temperature: 85°C
Light stand attachment: 5/8“
Fresnel lens code: < 6507 >
Light unit code: < 5060 >
Safety
clearance:
Position:
Under any circumstances do not under-run the safety
Tilt light unit max.
clearances given within the graphic to inflammable material!
45° upwards/down-
wards
in
operation!
HEDLER
®
S y s t e m l i c h t
max. +45°
max. -45°
0°
top
1m
0,5m
0,5m
TECHNICAL DATA Profilux
®
LED
1400
DMX
Type: Profilux
®
LED
1400
DMX
Voltage: 110 - 230 V ~ 1,0A 50/60 Hz
Power: 185 W LED
Risk group: 0-RG
Color: CRI > 95
Kelvin: 5600K
Safety class system: I
Protection category: IP30
Weight: 3600g
Ambient temperature (Ta): -15° - +40° C
Surface temperature: 85°C
Light stand attachment: 5/8“
Fresnel lens code: < 6507 >
Light unit code: < 5061 >
Safety
clearance:
Position:
Under any circumstances do not under-run the safety
Tilt light unit max.
clearances given within the graphic to inflammable material!
45° upwards/down-
wards
in
operation!
max. +45°
max. -45°
0°
top
1m
0,5m
0,5m
OPERATION MANUAL
KEY BUTTONS
On the back of the light units of the HEDLER Profilux
®
LED range there are several key buttons. By pressing them the indicated functions will
be switched alternatingly.
Fan 100% / Automatic
100% - the fan cooling of the light units of the HEDLER Profilux
®
LED range will be set to full power irrespective of the operating temperature;
Automatic - the power of the fan cooling will be regulated as a function of the operating temperature.
Dimmer OFF / ON
OFF - the continuous light output power is set to maximum (100%), the setting of the rotary potentiometer will be ignored;
ON - dimming function is available by turning the rotary potentiometer.
POWER OFF / ON
OFF - light unit will be switched off or rather into stand-by-mode (if the light unit has to be currentless you have to disconnect the light unit from
the electric power supply);
ON - light unit will be switched on with a Softstart function, the pre-set continuous light output power will be restored.
If not in use, please disconnect the light unit from the power supply completely.
STATUS-LEDs
Additionally you will find on the back of the light units of the HEDLER Profilux
®
LED range several status LEDs. Their operation mode will be
indicated by their glowing or blinking.
Error
Indicates an operating mode error of the HEDLER Profilux
®
LED
1400
/ HEDLER Profilux
®
. In this case the light unit has to be checked. Please
contact HEDLER Systemlicht GmbH directly or contact your photographic specialized dealer.
0049 (0)6482-918100
info@hedler.com
Please note:
If the light unit will be disconnected from the electric power supply the Error LED is glowing until the mains adapter is discharged. This is not
indicating an error.