15. The sink (item 2 illustration 1). In this sink water only shall be used.
Thinner/gun-wash must NOT under any circumstances be used in this machine.
PERMITTED SOLVENT DRUMS
The DRESTER BOXER DOUBLE A can be used with different types of drums, but they must comply with the following:
The drums must fit into the unit
The drums must be leak-free.
Check for local regulations concerning max allowed volume for keeping solvents at the site of the unit
Solvent drums are not provided by Hedson Technologies, thus Hedson Technologies does not take any responsibility
for the drums. Follow the solvent supplier’s instructions carefully.
COLLECTING TRAY
The unit must be installed in such a way as to prevent accidental leakage of solvent or contaminated water from
spreading into a drain water system, thus representing a hazard to the environment. This can be done by:
installing the unit in a location where floor and walls can hold any accidental drum leakage, or
equipping the unit with a collecting tray beneath the solvent drum and water container that is large enough to
hold the volume of at least one leaking item.