INSTR: 17625 REV: ECO-10003 2014-11-06 / TB GODK: SID: Sida 3 / 37
PURPOSE OF THE MACHINE
The unit is intended for cleaning of air-driven spray-guns using either thinner-based solvents or water-based solvents.
All other use of the unit are not allowed like:
-
Emptying excess paint into the unit
-
Cleaning of electric chargeable items
-
Collecting of various waste
-
Cleaning of textile materials
-
Storing of items
-
Cleaning of hands or other parts of the human body
-
Cleaning of any items for food or drinks
ASSEMBLY
First of all, check if the box containing the machine has been damaged during the transport. Remove the packaging and check
again that the machine has not been damaged during the transport. If so, report this immediately to the transport company.
To assemble the machine, please follow the enclosed guide No. 17624.
PLACING THE UNIT
The DRESTER Compact DC12 is equipment Category 2 (ref. ATEX-directive 94/9 EC) and may therefore be placed in locations
classified as Zone 1 (ref. ATEX-directive 1999/92 EC).
If the DRESTER Compact DC12 is installed in locations classified as Zone 2 or in unclassified locations, the following is valid
provided that the ventilation of the unit is installed as described further down in this manual
:
The space within 1 m of the DRESTER Compact DC12 is to be classified as Zone 2, and the inside of the ducting as Zone 1 (see
illustration 2).
Within these areas, all equipment such as electrical items must be approved for the Zones described. Equipment that generates
naked flames or sparks (e.g. welding or grinding equipment) may not be used in this area. Smoking is not permitted. If in any
doubt, please contact the local fire service authorities for advice.
This manual is part of the unit and must be available at all times.
INSTALLATION
Compressed air
The unit must be connected to compressed air of 7-12 bar (110-180 psi). When in use, the unit consumes 300 litres/min (11 cfm)
of air.
The air is to be connected to the ball valve at the rear of the machine (item 1 illustration 3).
To prevent pressure drops, the air line and couplings must be adequately dimensioned. The regulator on the unit is pre-set to 6.5
bar (100 psi). This is the optimal setting and must not be altered.
The compressed air supplied to the unit must be clean and dry. If it is not first led through a water trap and filter, it may cause
damage to the pneumatic components of the unit, which will invalidate any warranty claims.
Summary of Contents for DRESTER Compact DC12
Page 40: ...INSTR 17626 REV ECO 10003 2014 11 06 TBm GODK SID 3 11 2 Illustration 2 Illustration 3 1...
Page 41: ...INSTR 17626 REV ECO 10003 2014 11 06 TBm GODK SID 4 11 Illustration 4 Illustration 5...
Page 42: ...INSTR 17626 REV ECO 10003 2014 11 06 TBm GODK SID 5 11 17581 Illustration 6...
Page 43: ...INSTR 17626 REV ECO 10003 2014 11 06 TBm GODK SID 6 11 Illustration 8 Illustration 7...
Page 44: ...INSTR 17626 REV ECO 10003 2014 11 06 TBm GODK SID 7 11 Illustration 9 1 2 3...
Page 45: ...INSTR 17626 REV ECO 10003 2014 11 06 TBm GODK SID 8 11 Illustration 10...
Page 46: ...INSTR 17626 REV ECO 10003 2014 11 06 TBm GODK SID 9 11 Illustration 11 Illustration 12 2 1...
Page 47: ...INSTR 17626 REV ECO 10003 2014 11 06 TBm GODK SID 10 11 Illustration 13 Illustration 14...
Page 48: ...INSTR 17626 REV ECO 10003 2014 11 06 TBm GODK SID 11 11 Illustration 15 Illustration 16...