230754-EN rev.2 2017-07-13
GP 24
Error
code Text on display
Action
C001
Main frequency
incorrect
Call your Sales Rep.
C002
Main phase
missing
Check supply cable, wall
outlet and fuses.
C003
Main phase
order
Switch two phases in supply
plug.
A004
Pump motor
overcurrent
Check that the pump wheel
isn't stuck. Contact your
Sales Rep.
A005
Rotation motor
overcurrent
Check that the drive roll ro-
tates smoothly. Contact your
Sales Rep.
A007
Mixer motor
overcurrent
Check that the mixer axle
runs smoothly.
B011
Board over
temperature
Check ventilation, tem-
perature and dust around
electric box. Let the machine
cool down and try again.
B016
Arm overcur-
rent
Contact your Sales Rep.
B017
Arm stall
Remove linear actuator and
check that the dynamic arm
runs smoothly. Contact your
Sales Rep.
A018
Fuse MF2 over-
load
Replace control card.
A019
Fuse MF3
overload
Check door sensor and
cable.
A020
Fuse MF4
overload
Check air blow solenoid
valve and cable.
A021
Fuse MF5 over-
load
Replace control card.
A022
Fuse MF9 over-
load
Look for short circuit in
cables and contacts to linear
actuator.
A023
Pump motor
phase missing
Check that cable to pump
motor is not damaged.
A024
Rotation motor
phase missing
Check that cable to rotation
motor is not damaged.
A025
Mixer motor
phase missing
Check that cable to mixer
motor is not damaged.
A026
Pump motor off
current failure
Call your Sales Rep.
A027
Misc sensor off
current failure
Call your Sales Rep.
B028
Heater
undercurrent
Check that cable to heater is
not damaged.
B029
Heater
overcurrent
Check that cable to heater is
not damaged.
DISPLAY MESSAGES
Error
code Text on display
Action
B030
Water
temperature
sensor failure
Check that tempsensor
cable to heater is not dam-
aged.
B031
Water over
temperature
Check that cable to heater is
not damaged.
C041
Cannot read
NVM, restart
machine
Restart the machine.
A045
Cylinder 1
not retracted
Check end position
sensor 1-.
A046
Cylinder 1
not extended
Check end position
sensor 1+.
A047
Cylinder 2
not retracted
Check end position
sensor 2-.
A048
Cylinder 2
not extended
Check end position
sensor 2+.
A049
Cylinder 3
not retracted
Check end position
sensor 3-.
A050
Cylinder 3
not extended
Check end position
sensor 3+.
A051
Cylinder 4
not retracted
Check end position
sensor 4-.
A052
Cylinder 4
not extended
Check end position
sensor 4+.
A053
Cylinder 5
not retracted
Check end position
sensor 5-.
A054
Cylinder 5
not extended
Check end position
sensor 5+.
A055
Cylinder 6
not retracted
Check end position
sensor 6-.
A056
Cylinder 6
not extended
Check end position
sensor 6+.
C057
Emergency
stop activated
Reset emergency stop
and restart machine.
A060
Problem side
support
Check that the side support
can move freely i.e no wheel
inside machine.
B061
Air pressure
low
Check that compressed
air is connected.
A062
Trolley out of
position
Replace the trolley
in start position.
C063
Terminal box
communication
loss
Check that the cable to the
terminal box is not damaged.
A064
Terminal box
MF1 overload
Check end position sensors
and pressure guard.
A065
Terminal box
MF2 overload
Check warning light,
buzzer and solenoids.
See chapter 11.5.9 Alarm Log