Safety
Suprasetter A52/A75 – Installation
General
Remote Service is possible only when requested by a customer and only with the consent of this cus-
tomer. The provider (WEBEX) warrants a safe data link. No command execution takes place during
transmission interference. The customer can terminate the link by closing the Internet Explorers
(highest priority).
A unique session number only valid for the duration of the link must be specified. The after-sales ser-
vice communicates this number to the customer.
• The customer allows access to one program only.
• The customer can trace all action on the monitor.
With the key-operated switch switched on, i.e. with the safety loop bypassed, the software disables
the "normal" imaging programs. Imaging is not possible in this mode because the laser cannot be
activated when the key-operated switch is used.
For maintenance, set parameters 4-26009 and 26031 to 0.
•
DIAG
= Diagnostic service software for actuating all individual functions
•
GUI
= CTP User Interface for activating all single and interrelated functions
• Service terminal
You can always stop the machine on site with the power switch or the EMERGENCY STOP button.
The machine's relatively small size and its construction allows a clear overview, making hazard points
(plate loading table, exposure cylinder, laser module slide) visible from almost any point around the
machine. The potential risk arising from the plate loading table is slight as it moves very slowly and
can be stopped by hand.
Laser module slide and cylinder are not directly accessible. The laser module carriage moves rela-
tively slowly.
Remote Control Procedure
When the key-operated switch whose position is polled has been switched on, local confirmation is
requested acoustically and optically prior to a control run by the DIAG or CTP User Interface pro-
grams.
Control is enabled only when the customer gives his/her consent by pressing the input key at the
front right of the machine. Confirmation is valid as long as the key-operated switch remains in its
position. It is required again when the key-operated switch has been switched off and on again.
Summary of Contents for Suprasetter A52
Page 6: ......
Page 24: ...Safety 22 Fig 24 Filter replacement Fig 13 4 On the filter unit ...
Page 26: ...Safety 24 Fig 26 Warning sign copy template ...
Page 36: ...Installation Preparation 34 Pallet Installation Instructions ...
Page 82: ...Technical Data 80 Resolution 1000 pixels cm 2540 dpi Type Value Comment ...
Page 84: ......
Page 85: ......