Installation
Tab. LEDs on PCB 00.785.1151
Tab. Filling
H1
H2
H3
Description
OFF
OFF
OFF
No error
Flashing OFF
OFF
Warning: Water below MAX mark
Flashing OFF
Flashing Error: Water below MIN mark
ON
OFF
Flashing Error: Water flow < 0.5l/min.
OFF
ON
Flashing Error: Fan speed < 1500 rpm.
ON
ON
Flashing Error: Temperature < 15°C or > 35°C or controller faulty
ON
ON
OFF
In the test mode: Water above the MIN and MAX marks
OFF
ON
OFF
In the test mode: Water above the MIN mark
Pos. Designation
Reference No. Comment
Scope of delivery
1
Measuring cup
Recommended:
2 liters
Not included in the Suprasetter shipment
Must be provided by customer.
2
Funnel
Part of the Suprasetter
3
Filler hose
00.471.0343
Part of the Suprasetter
4
Vent hose
PL.485.7496
Part of the Suprasetter
5
Container for
liquids
00.471.0343
Container free of
chemical resi-
dues
Volume: At least
2 liters
Not included in the Suprasetter shipment
Must be provided by customer.
6
Glysantin G48 00.580.6786
1 can (1.5 liters) supplied with Suprasetter
7
Water
Requirements:
Clean drinking
water that is not
too hard and is
without chlorine
Not included in the Suprasetter shipment
Must be provided by customer.
8
Shutoff valve
PJ.187.066/01
Part of the Suprasetter
9
Service push-
button with
connector
BP.007.0052/01
Not included in the Suprasetter shipment
(service tool)
10
Absorptive
cloth
Not included in the Suprasetter shipment
Must be provided by customer.
Summary of Contents for Suprasetter A52
Page 6: ......
Page 24: ...Safety 22 Fig 24 Filter replacement Fig 13 4 On the filter unit ...
Page 26: ...Safety 24 Fig 26 Warning sign copy template ...
Page 36: ...Installation Preparation 34 Pallet Installation Instructions ...
Page 82: ...Technical Data 80 Resolution 1000 pixels cm 2540 dpi Type Value Comment ...
Page 84: ......
Page 85: ......