Commissioning | Configuring the axes
Extended TXT schema
The extended TXT file contains the deviations of the supporting points from the
nominal values on the X and Y axes.
The following example shows a grid with 5 x 5 supporting points with a spacing of
25 mm on the X axis and 20 mm on the Y axis.
Example
NLEC Data File
0.91
// Serial Number = CA-1288-6631-1710
MM
ON
Number of Grid Points (x, y):
5
5
Grid Block Size (x, y):
25.0
20.0
Offset:
0
0
Station (1, 1)
0.00000
0.00000
Station (2, 1)
0.00120
-0.00100
Station (3, 1)
0.00030
-0.00060
Station (4, 1)
0.00100
0.00160
Station (5, 1)
0.00210
0.00000
Station (1, 2)
0.00005
0.00200
Station (2, 2)
0.00130
0.00210
Station (3, 2)
0.00130
0.00220
Station (4, 2)
0.00050
0.00230
Station (5, 2)
-0.00040
0.00030
Station (1, 3)
-0.00010
-0.00020
Station (2, 3)
-0.00190
-0.00210
Station (3, 3)
-0.00010
0.00010
Station (4, 3)
0.00040
0.00210
Station (5, 3)
0.00190
0.00080
Station (1, 4)
7
HEIDENHAIN | GAGE-CHEK 2000 | Operating Instructions | 08/2020
105
Summary of Contents for GAGE-CHEK 2000 Series
Page 1: ...GAGE CHEK 2000 Operating Instructions Evaluation Unit English en 08 2020 ...
Page 12: ......
Page 13: ...1 Fundamentals ...
Page 22: ......
Page 23: ...2 Safety ...
Page 28: ......
Page 29: ...3 Transport and storage ...
Page 34: ......
Page 35: ...4 Mounting ...
Page 41: ...5 Installation ...
Page 51: ...6 Basic operation ...
Page 74: ......
Page 75: ...7 Commissioning ...
Page 119: ...8 Setup ...
Page 154: ......
Page 155: ...9 Measuring ...
Page 169: ...10 File management ...
Page 176: ......
Page 177: ...11 Settings ...
Page 210: ......
Page 211: ...12 Servicing and maintenance ...
Page 220: ......
Page 221: ...13 What to do if ...
Page 225: ...14 Removal and disposal ...
Page 227: ...15 Specifications ...