Air Bleeding Instructions for Air / Manual Service Jacks 

HEIN-WERNER Models HW93662 (10 Ton) & HW93667 (4 Ton)  

Hein-Werner Automotive 

10939 N. Pomona Avenue, Kansas City, Missouri 64153, USA 

Telephone: (816) 891-6390, Toll Free (888) 332-6419 

heinwerner-automotive.com

 

 

Step 6:  

  Use a Hex Wrench, to 

loosen the AIR MOTOR 
VENT PLUG by turning 
Counter Clockwise. 

  Remove the AIR 

MOTOR VENT PLUG.  
Retain for later re-
installation. 

 

 

 

 

 

 

 

Step 7:  

  Turn the RELEASE 

VALVE KNOB 
counter-clockwise to 
allow the LIFT ARM to 
lower. 

  After making note of 

Step 8, manually pump 
the HANDLE, as the 
LIFT ARM moves 
downward. 

 

 

 
 

 

 

 

 

Step 8:  

  When oil is expelled 

from the AIR MOTOR 
VENT PLUG hole, 
quickly re-install the AIR 
MOTOR VENT PLUG. 

  Next, securely tighten 

the AIR MOTOR VENT 
PLUG. 

  If oil is not expelled, as 

shown, repeat Steps 4, 
5 and 7. 

 

 

 

 

 

 

 

Step 9:  

  Attach an air compressor hose to the AIR 

CONTROL VALVE located on the HANDLE of the 
unit.  

 

 

 

 

 

Summary of Contents for HW93662

Page 1: ... this procedure NO LOAD should be placed on this equipment during this procedure Any persons not involved in the work should leave the area Work area should be clean and free of any hazards such as oil spills Only trained competent adults should perform this procedure Use ONLY approved Hydraulic Jack Oil when adding or replacing oil in a hydraulic jack NEVER use brake fluid turbine oil transmissio...

Page 2: ...6419 heinwerner automotive com Step 2 Open the COVER PLATE Step 3 Locate and remove AIR VENT SCREW Step 4 Verify that the Release Valve is in the CLOSED position by turning the RELEASE VALVE KNOB clockwise until resistance is felt Step 5 Lift the jack manually by pumping the HANDLE until the LIFT ARM has reached its maximum height Approximate Maximum Height 25 1 2 648mm for HW93662 10 Ton 25 3 4 6...

Page 3: ...se Remove the AIR MOTOR VENT PLUG Retain for later re installation Step 7 Turn the RELEASE VALVE KNOB counter clockwise to allow the LIFT ARM to lower After making note of Step 8 manually pump the HANDLE as the LIFT ARM moves downward Step 8 When oil is expelled from the AIR MOTOR VENT PLUG hole quickly re install the AIR MOTOR VENT PLUG Next securely tighten the AIR MOTOR VENT PLUG If oil is not ...

Page 4: ... 1 2 648mm for HW93662 10 Ton 25 3 4 654mm for HW93667 4 Ton WARNING Use ONLY approved Hydraulic Jack Oil when adding or replacing oil in a hydraulic jack NEVER use brake fluid turbine oil transmission fluid motor oil or glycerin in a Hydraulic Jack Improper fluid can cause failure of the jack and the potential for sudden and immediate loss of load Step 11 Add oil to replace the expelled oil using...