after 100 hours of operation
The flexible drive is fitted with sealed and permanently lubricated ball be
-
arings. The rotating shaft bore must, however, be greased at regular in-
tervals (after approximately 100 hours of operation or every 2 years). To
perform this task dismantle the flexible drive in order to remove old grease
residue from the shaft bore. Then re-lubricate the shaft bore along its whole
length with fresh, high-quality mineral grease.
4.3.3 Rigid drive downtube
The rigid drive downtube is fitted with sealed and permanently lubricated
ball bearings. The rotating cogs of the universal joint must, however, be
lubricated at regular intervals during use (approximately every 2 operating
hours). Lubricate the shaft at the lubrication points provided in accordance
with Diag. 7, pos. b. Only high quality mineral oil is to be used for this pur-
pose (engine or gearbox oil).
4.3.4 Shearing handpiece
See operating instructions for shearing handpiece.
4.4
Storing the machine
CAUTION!
Get into the habit of always giving the shearing plant a good cle-
an after use, store the unit in a dry and clean location out of the
reach of children.
EVO Shearing Plant – Translation of the original instructions
11