5
Troubleshooting and repairs
This product has been developed and assembled using the best individu-
al components available. It is designed to give longevity and high perfor-
mance. If spare parts are used during the life of this product, please en-
sure that they are genuine Heiniger parts. Failure to use genuine Heiniger
spares may reduce the performance of this precision engineered product
and will void any warranty claim.
5.1
Introduction
WARNING!
The following troubleshooting guide will aid in determining pro-
blems and offer a solution. An authorised service point may only
carry out solutions that appears against a dark background.
An authorised service agent is to be contacted in the event of
malfunctions that are not contained in this manual.
5.2
Troubleshooting
Malfunction
Cause
Rectification
Motor does not run.
No power.
Power supply and/or fuse
faulty.
Cable faulty.
Have the cable replaced.
Switch faulty.
Have the switch replaced.
Motor faulty.
Have the motor replaced.
Control unit faulty.
Have control unit replaced.
Capacitors faulty.
Have the capacitors re-
placed.
Motor always switching
off.
Cutter blocked.
Remove blockage.
Mechanical damage in
the shearing handpiece,
in the rigid drive downtu-
be or flexible drive.
For the purposes of fault
finding first of all uncouple
the shearing handpiece
and restart the plant. If the
fault persists, uncouple
the rigid drive downtube
or flexible drive from the
shearing plant. Rectify any
damage.
If the fault still persists,
then have the shearing
plant repaired.
Bearing in the shearing
plant faulty.
Have the bearing replaced.
Motor system does not
switch off by lock up.
The belt is slipping.
Have the belt replaced.
EVO Shearing Plant – Translation of the original instructions
12