4
COMPRESSOR
may occur. If you are not sure about the voltage
values, do not connect the compressor. If the
network voltage is too low, the motor may
damage. Always remove the plug from the socket
before any maintenance or adjustment operations.
Do not try to remove parts from the compressor
while under pressure.
Do not attempt to remove electrical components
while the compressor is still connected to the
power source.
Turn off the equipment and unplug it. Do not
adjust the safety valve.
Do not use extension cords. If the exhaust valve
under the pressure controller case (2) is not
working when you press the on / off button, turn
off the power supply and try to identify the
malfunction cause.
Make sure that the greasing oil is clean and that its
level is maintained in the middle of the red circle
on the level indicator (17).
Be careful when you aerate the pressure tank –
compressed air can be extremely dangerous. Make
sure that air blowing does not engage dust, rocks
or other foreign bodies. Please ensure that the air
is exhausted in safe conditions.
In order to reduce fire or explosion risks, do not
spray flammable liquids in confined spaces. The
motor produces sparks during its normal
operation. When these sparks come into contact
with gasoline vapours or flammable liquids, they
cause fires or explosions.
Use the compressor in well ventilated rooms and
do not smoke while spray painting. Do not paint in
the proximity of sparks or open flames. Place the
compressor as far as possible from the spraying
location.
Do not inhale directly the compressed air
produced by the compressor. Do not use the
compressed air to fill breathing cylinders.
Do not use welding equipment near the
compressor. Do not weld anything on the pressure
vessel of the compressor; it could dangerously
loosen the tank.
Do not operate the compressor in the rain or
placed on humid surfaces. Electrocution hazard!
Always turn off the compressor after using it or
before any maintenance operation.
Press the on / off button, wait for the compressed
air to be exhausted by the exhaust valve and then
unplug the compressor.
Check the maximum allowable pressure of all the
equipment used with the compressor. The
pressure delivered by the compressor must be
adjusted so that it does not exceed the maximum
allowable pressure of the used devices and
accessories.
In order to reduce the risk of injury by contact with
mobile parts, do not use the compressor if its
protection is disassembled. Allow hot parts to cool
before touching them.
Read carefully all the labels and instructions on the
paint bottle or other spraying materials.
Strictly observe all safety instructions. Use the
breathing mask if there is any risk of inhaling
sprayed material.
Before using the mask, check if it works properly.
Use goggles whenever using the compressor.
Do not point the accessory nozzle towards your
body or other persons.
Do not attempt to adjust the pressure controller or
the exhaust valve under the case.
Drain the condensation from the tank on a daily
basis in order to avoid corrosion.
Pull the safety valve ring to make sure that it works
properly.
Place the compressor at minimum 300 mm away
from the wall to provide sufficient ventilation for
cooling purposes.
Before transporting the compressor, exhaust the
air from the tank, then from the compressor and
fix the equipment well.
Protect the air hose and the cables from damages.
Check regularly if they have weak points or signs of
wear and replace them if applicable.
Do not use the extension cord for this product.
Instead of any extension cord, use an additional air
hose to avoid power decrease and motor damage.
After a longer period of use, the external metal
parts may overheat.
Summary of Contents for VCMP002