5. Speed Setpoint Adjusters and Sensors
HELENOS III
10
5.6. Temperature Sensor TS - 2000 F for Measuring Fluid Temperatures
(EDV- No.: 600 00 034 00)
Measuring range
-20°C to +130°C
Accuracy ±
1.5°C
Resistance at 25°C (R25)
2,000 Ohm ±0.5%
Maximum operating voltage
10 V
Maximum operating current
5 mA
Recommended operating current
approx. 1 mA
Time constant in fluids
approx. 13 s
Admissible socket temperature range
-40°C to +105°C
Protection type
IP 65
Vibration
<10 g. 10 – 100 Hz
Shock
<50 g. 11 ms half-sine wave
Tightening moment
100 Nm ±15 %
Corresponding connector
SVM - TS - 2K (EDV- No.: 010 02 170 00)
B
A
Seal Ring DIN 7603-14x18 (Cu)
Pin Configuration:
B = -
20
SW
5/
8
"-
24
M
1
4x
1,
5
8
h
7
16
28
17,5
56,5
A = +
Fig. 6: Temperature Sensor TS - 2000 F
PT 1000- types can be used alternatively.
For measuring gas temperatures PT 1000- types must be used.