14 Parameter Description
92
KRONOS 20
14.5
List 4: Characteristics and Maps
No. Name
Signification
6000 MisfireWarn:P(x)
up to
6007
Level:
4
Range:
0..2500 kW
Page(s):
Output power values for misfire warning characteristics
6010 MisfireWarn:nVar(x)
up to
6017
Level:
4
Range:
0..65,535
Page(s):
Speed variance values for misfire warning characteris-
tics
6020 MisfireEcy:P(x)
up to
6027
Level:
4
Range:
0..2500 kW
Page(s):
Output power values for misfire emergency characteris-
tics
6030 MisfireEcy:nVar(x)
up to
6037
Level:
4
Range:
0..65,535
Page(s):
Speed variance values for misfire emergency character-
istics
7400 LambdaMap:n(x)
up to
7409
Level:
4
Range:
0..4000 1/min
Page(s):
Speed values for lambda map
7450 LambdaMap:p(x)
up to
7459
Level:
4
Range:
0..5 bar
Page(s):
Manifold pressure values for lambda map
7500 LambdaMap:Lambda(x)
up to
7599
Level:
4
Range:
0..2,5
Page(s):
Lambda values for lambda map
7600 GasValve:A(x)
up to
7624
Level:
6
Range:
0..65535 mm²
Page(s):
Cross sectional area for the gas valve characteristics
7650 GasValve:Pos(x)
up to
7674
Level:
6
Range:
0..0 steps
Page(s):
Position stepper motor for the gas valve characteristic
Range depends on gas valve size
7900 TempIn1:digit(x)
up to
7914
Level:
6
Range:
0..65535
Page(s):
AD-converter values for temperature linearization char-
acteristic
7920 TempIn1:T(x)
up to
7934
Level:
6
Range:
-100..1000 °C
Page(s):
Temperature values for temperature linearization
characteristic
Summary of Contents for E-LES 30
Page 2: ......
Page 8: ......
Page 104: ...17 Order Form for KRONOS Systems 96 KRONOS 20 17 Order Form for KRONOS Systems...