3 Sensors
KRONOS 20
15
Adequate mounting into the intake manifold (pressure taping point at the top of the
manifold, joint bent downwards) must make sure that no condensate accumulates inside
the pressure cell.
In addition, the sensor should neither be mounted too close to the throttle valve nor to
the cylinder intakes.
3.3.4
ATEX Certification for Double Sensor P/T-S-01
The double sensor P/T-S-01 is ATEX-certified according to EN 60079-0:2004 (General
requirements) and EN 60 079-15:2003 (type of protection "n"). If the sensor is used in
such an ambient and require an ATEX certificate, the wiring of the sensor must be done
by HEINZMANN too. In this case, HEINZMANN will attach the following sticker to
the wire close to the sensor plug:
HEINZMANN GmbH & Co. KG Germany
www.heinzmann.de Tel.: +49 7673 8208-0
Type: P/T-S-01, II3G Ex nA II T4
T
cable
: -5°C to +80°C, T
housing
: -40°C to +130°C
TÜV 07 ATEX 552892X
WARNING - EXPLOSION HAZARD -
DO NOT DISCONNECT WHILE CIRCUIT
IS LIVE UNLESS AREA IS KNOWN
TO BE NON-HAZARDOUS
Figure 6: Information Sign on Double Sensor Cable, Front and Back
3.4
λ
Sensor LSM 11 for Exhaust Gas Measurement (optional)
3.4.1
Technical Data
Power supply for heating
12..13 V AC/DC
Current consumption
1.25 mA at 12 V
Signal output voltage
0..0.9 V DC
Permanent exhaust gas temperature
+150°C to +600°C
Maximum exhaust gas temperature
+800°C
Storage temperature
-40°C to +100°C
Part-no.:
Sensor 010-80-020-00
corresponding cable
600-81-054-00
Summary of Contents for E-LES 30